background image

 

Seal gaps between DELTA®-FL and any posts or penetrations with low expansion spray foam    

  to prevent the passage of water vapor into living area.

 

Access to floor drains and clean-outs must be maintained. Cut DELTA®-FL around drains or    

  clean-outs. Seal DELTA®-FL with low expansion spray foam (see Detail 4).

Carpet, Vinyl, Hardwood, or Other Floor Covering Requiring Rigid Substrate

 

Place 4’ x 8’ sheets of minimum 7/16” OSB/ Plywood sheets over DELTA®-FL. 

 

Pre-drill the wood sheets and the concrete according to the fastening pattern (see Detail 4).

 

Apply a small amount of silicone caulking on the thread of the fasteners and into    

 

  the pre-drilled hole of the wood sheets prior to installing the Tapcon® screws.

 

Install 8 (eight) Tapcon® screws per sheet (see Detail 5).

 

Inspect the wood sheets for areas with bounce, tapping, or squeaks. Add additional fasteners   

  where necessary. 

 

Some hardwood floors are nailed to the substrate. When these types of hardwood floors  

 

  are installed, ensure that the fasteners do not penetrate the DELTA®-FL. Note that some  

 

  hardwood floors may not be recommended for below grade use. Check with your flooring    

 manufacturer.

 

Install final floor as per manufacturer’s recommendations.

Floating Laminate and Engineered Wood-Flooring Installations

 

 

Place recommended underlayment foam over DELTA®-FL as indicated by the laminate/ 

 

  engineered wood floor manufacturer.

 

Install the laminate/engineered wood flooring system as recommended by  

 

 

  manufacturer (see Detail 6).

General Notes

 

Transitions: Consider any transitions from one finished flooring system to another (i.e.  

 

  laminate to carpet). The elevation difference may affect your final installation. 

 

Material allowance: Always allow 10% to 15% extra material to accommodate doorways,  

 

  cutouts and waste.

 

Always follow local Building Code Requirements whenever building/renovating.

Added Warmth and Comfort

 

DELTA®-FL acts as a vapor barrier. An additional vapor barrier is not required on the concrete    

 floor. 

 

Extruded or expanded rigid insulation boards can be installed over the DELTA®-FL prior to the  

  installation of the finished flooring.  

Limitations

 

Product is not desinged for pernament UV exposure. Always cover as soon as possible.

Load Considerations

 

DELTA®-FL features high compressive strength.  Typical household items like refrigerators,  

 

  billiards tables and furniture can be placed onto the finished flooring without compromising   

  the DELTA®-FL.

Disposal of Waste

 

DELTA®-FL is made from environmentally friendly HDPE.

 

Waste can be recycled where facilities allow.

For technical support, call our Technical Support Team at 1-888-433-5824 extension 326, or visit 

www.dorken.com

4

5

3

6

The information printed in this brochure 

reflects product information and 

specifications at the date of printing. 

The manufacturer reserves the right to 

make changes when necessary. All rights 

reserved.

DELTA®-branded quality products 

manufactured by Cosella-Dörken.

CD 06/20/17  10

DEL

TA® is a r

eg

ist

er

ed tr

ademar

k of E

w

ald D

ör

ken A

G, Her

decke

, G

er

man

y

Dörken Systems Inc.
4655 Delta Way 
Beamsville, Ontario 
L0R 1B4
1-(905) 563-3255 
Fax: (905) 563-5582 
[email protected] 
www.dorken.com

DÖRKEN

GROUP company

Reviews: