1.3 Rotary Joint Harwin 12/Omnetics PZN12 Adapter Kit

To integrate the rotary joint within electrophysiology systems that use

Omnetics PZN-12 connectors

, an adapter kit

can be provided. These elements allow a Harwin-connectorized rotary joint to serve as a rotary joint for Omnetics con-

nectorized systems. The adapter system is composed of the following elements.

Figure 1.2:

Harwin-Omnetics Adapters and Parts

• The

MIRROR Adapter

is a cable with a

Female Harwin 12-pin connector

on one side and a

Omnetics PZN12

connector

on the other. To use, simply insert the Female Harwin connector in the Male Harwin connector on

the

Stator

side of the rotary joint. The pinout inside this adapter is mirrored to take into account the connector

mirroring in a

Omnetics PZN12/Omnetics PZN12

cable.

• The

STRAIGHT Adapter

is a simple

Female Harwin 12-pin connector

/

Omnetics PZN12 connector

adapter. To

use, simply insert the Female Harwin connector in the Male Harwin connector on the

Rotor

side of the rotary

joint.

Figure 1.3:

Adapters Connected to AHRJ (example), STRAIGHT on Rotor (yellow) and MIRROR on Stator (black)

Chapter 1. Overview

5

Summary of Contents for Electrical Rotary Joint

Page 1: ...Electrical Rotary Joint User Manual Version 1 1 1...

Page 2: ...lectrical Rotary Joint Holders 4 1 3 Rotary Joint Harwin 12 Omnetics PZN12 Adapter Kit 5 2 Operations Guide 6 2 1 Rotary Joint Holders 6 2 2 Electrical Optical Cables 9 3 Specifications 12 4 Support 1...

Page 3: ...it signal It is composed of a Stator which stays immo bile and a Rotor that moves Fig 1 1b The electrical signal is transmitted through 2 possible types of connectors Male Harwin 6 or 12 contacts or F...

Page 4: ...usedincombinationwiththeHolder FRJ smallortheHolder FRJ large If the rotary joint is used only for electric signal the Holder FRJ large alone Fig 1 1 The gimbal mount GH FRJ Fig 1 1 can also be used w...

Page 5: ...win 12 pin connector on one side and a Omnetics PZN12 connector on the other To use simply insert the Female Harwin connector in the Male Harwin connector on the Stator side of the rotary joint The pi...

Page 6: ...2 Operations Guide 2 1 Rotary Joint Holders 2 1 1 Holder ERJ a b c d Figure 2 1 Installation of the rotary joints in the Holder ERJ 6...

Page 7: ...er FRJ small is then be attached to the Holder ERJ frame 1 using 1 4 or M6 screws 2 and bolts 3 Fig 2 1d See Figure 2 2a for the final result For installation using the 1x2 Fiber optic Rotary Joint In...

Page 8: ...or M6 screws Figure 2 3 Installation of the ERJ in the Holder FRJ large 2 1 3 GH FRJ The Gimbal Holder allows swivel movement of the rotary joint along 2 axes The rotary joint is to be threaded into t...

Page 9: ...stalling the cables When not in use install plastic caps on connectors for protection and cleanliness 2 Connect the signal electrical cable to the fixed electrical connector Fig 2 5a and 2 5b 3 Connec...

Page 10: ...a subject patch cord connecting to the experimental subject 1 Connect the signal patch cord to the fixed connector of the optical rotary joint 2 Install the ERJ Holder as shown in section 2 1 1 3 Sele...

Page 11: ...Figure 2 7 Electrical and Fiber optic Rotary Joints Cable Installation Chapter 2 Operations Guide 11...

Page 12: ...ctrical Connector Configuration Male on rotary joint Female on adapter Table 3 2 HDMI Electrical Connector Configuration Male on cable Female on rotary joint Table 3 3 HDMI Electrical Connector Pinout...

Page 13: ...resistance 500 m Resistance variation during rotation 100 m 5 VDC During constant rotation Start up torque 0 9 mN m for 6 contacts Typical Value 1 9 mN m for 12 contacts Typical Value Rotation speed...

Page 14: ...urn instructions This warranty will not be applicable if the unit is damaged or needs to be repaired as a result of improper use or operation outside the conditions stated in this manual For more info...