(SIDE 2 OF 2)

Adjusting the HOT LIMIT RING (ANTI−SCALD STOP RING)
The cartridge fitted in this mixer has been factory pre−set to deliver

the maximum available hot water temperature. To use the ANTI−SCALD

feature adjust the cartridge as follows:−
Carefully remove plug (2). Using 2.5mm allen key (3) loosen screw (4)

and remove handle (1). Unscrew cap (5) taking care not to damage the

decorative finish. (See details on side 1 of this sheet.)
To remove the Hot Limit Ring (7) from the cartridge (9), use a small thin

flat bladed screwdriver and carefully lever in an upwards direction.

Rotate the Ring (7) in a clockwise direction then refit the Ring (7) onto

the cartridge (9).

Note:− Start by rotating the Ring (7) in small increments, then check the

hot water temperature with the mixer handle in the fully open maximum

hot water position. The Ring (7) can be removed & repositioned until the

desired maximum hot water temperature is achieved.

Ensure the Ring (7) is pushed fully down onto the cartridge (9), then replace

cap (5), tightening by hand. Fit handle (1), taking care that it is pushed

fully down, tighten screw (4) and replace plug (2).

PLUMBERS ADJUSTMENT INSTRUCTIONS

JOVIAN − SINK MIXER

WATER EFFICIENT TAPWARE

(NOMINAL FLOW RATE = 7 L/min)

Adjusting the WATER VOLUME LIMIT SCREW
The cartridge fitted in this mixer has been factory pre−set to deliver

the maximum flow of water when the mixer handle is in the fully open

position.

Important Note:− This Sink Mixer is already fitted with a 7.0 L/min

flow regulated aerator insert. Lower flow rates may not be suitable

for connection to some Instantaneous Gas Water Heaters, some Tempering

Valves, some Solar Water Heaters & some Thermostatic Mixing Valves.

Check with the manufacturers of these products.

However, the flow of water may be reduced further by adjusting the cartridge

as follows:−

Carefully remove plug (2). Using 2.5mm allen key (3) loosen screw (4)

and remove handle (1). Unscrew cap (5) taking care not to damage the

decorative finish. (See details on side 1 of this sheet.)

Using a small thin flat bladed screwdriver, adjust screw (8) in an anti−clockwise

direction.

Note:− Start by rotating the Screw (8) in small amounts then check the

flow of water with the mixer handle in the fully open position. Readjust

the screw until the desired water flow is achieved.

Replace cap (5), tightening by hand. Fit handle (1), taking care that it is

pushed fully down, tighten screw (4) and replace plug (2).