background image

H 2 S - 3 0

User Manual

Version 1.3

Compliant with H2S-30 Firmware version 1.6.0

and H2S-30 Doremi Universal Interface Software 4.2.3

H2S.OM.001539.DRM                                           Page 1                                                         Version 1.3

    Doremi Labs

Summary of Contents for H2S-30

Page 1: ...H2S 30 User Manual Version 1 3 Compliant with H2S 30 Firmware version 1 6 0 and H2S 30 Doremi Universal Interface Software 4 2 3 H2S OM 001539 DRM Page 1 Version 1 3 Doremi Labs ...

Page 2: ... 3 7 System Menu 20 3 8 Status Menu 20 4 Infrared Remote Controller 21 4 1 Remote Controller Overview 21 4 2 Remote Controller Functions 22 4 3 Input Source Setting 23 4 3 1 SDI Output Format 23 4 3 2 Setting the IR Channel 24 5 Doremi Universal Interface Software DUIS 25 5 1 DUIS Installation 25 5 2 Doremi Universal Interface Software Overview 28 5 3 Settings Field 29 5 4 Tabs Description 31 5 4 ...

Page 3: ... Warranty The hardware warranty can be found at the following location http www doremilabs com support proav support proav warranties HDMI The terms HDMI and HDMI High Definition Multimedia Interface and the HDMI Logo are trademarks or registered trademarks of HDMI Licensing LLC in the United States and other countries H2S OM 001539 DRM Page 3 Version 1 3 Doremi Labs ...

Page 4: ...equirements in the surrounding area If in doubt consult a qualified electrician or a Doremi Labs dealer H2S 30 Power Ratings The H2S 30 should only be used with a Doremi approved power supply Power Supply Specifications AC Input 100 240V 1 2A 50 60Hz Output 12V DC 3 0A 36W Max H2S 30 Power Requirements 12V DC 12A H2S OM 001539 DRM Page 4 Version 1 3 Doremi Labs ...

Page 5: ... circuitry as well as the external finish keep the H2S 30 away from direct sources of heat heater vents stoves radiators Avoid using flammable aerosols near the H2S 30 They can damage the surface area and may ignite Do not use denatured alcohol paint thinner or similar chemicals to clean the H2S 30 This can damage the unit Modification of this equipment is dangerous and can result in the functions...

Page 6: ... a le r t th e u s e r to th e p r e s e n c e o f u n in s u la te d d a n g e r o u s v o lta g e w ith in th e p r o d u c t s e n c lo s u r e th a t m a y b e o f s u f f ic ie n t m a g n itu d e to c o n s titu te a r is k o f e le c tr ic s h o c k T h e e x c la m a tio n p o in t w ith in a n e q u ila te r a l tr ia n g le is in te n d e d to a le r t th e u s e r to th e p r e s e n c ...

Page 7: ...ommunity The marking is indicative that the device meets or exceeds the following technical standards EN 55022 Limits and Methods of Measurement of Radio Interface Characteristics of Information Technology Equipment A Declaration of Conformity in accordance with the above standard has been made and is on file at Doremi H2S OM 001539 DRM Page 7 Version 1 3 Doremi Labs ...

Page 8: ...ce Software DUIS It explains all features of the H2S as well as the infrared remote control and how to upgrade the firmware 1 2 Software Version DUIS software version 4 2 3 H2S 30 Firmware version 1 6 0 1 3 Contact Information If in need of help or assistance please contact Doremi Labs Technical Services at 1 818 562 1101 or email at proavsupport doremilabs com H2S OM 001539 DRM Page 8 Version 1 3...

Page 9: ...oth SD and HD video and employs 12 bit bi cubic interpolation to ensure the highest quality picture It also supports 3G SDI and can tackle many conversion tasks 2 1 1 H2S 30 Top View Figure 1 H2S 30 Top View 2 1 2 H2S 30 Front Panel The H2S 30 front panel is illustrated below Figure 2 H2S 30 Front Panel View H2S OM 001539 DRM Page 9 Version 1 3 Doremi Labs Infrared Sensor Headphone Jack Power LED ...

Page 10: ...lowing connectors Connector Description USB USB connector HDMI in HDMI input connector SDI A out SDI output connector Link A SDI B out SDI output connector Link B SYNC in Sync input connector Power Power supply connector H2S OM 001539 DRM Page 10 Version 1 3 Doremi Labs USB Power Connector HDMI in SYNC in SDI A out SDI B out ...

Page 11: ... 1280x720 720p 1024x768 XGA 1280x768 WXGA 1364x768 WXGA 1366x768 WXGA 1536x768 1536x768 1152x864 XGA 1280x960 SXGA 1280x1024 SXGA 1364x1024 1364x1024 1400x1050 SXGA 1680x1050 WSXGA 1920x1080i 1080i 1920x1080p 1080p 2048x1080 2Kp 1600x1200 UXGA 1920x1200 WUXGA SD SDI NTSC PAL SMPTE 259M C 4 3 or 16 9 SMPTE 259M C 4 3 or 16 9 HD SDI all HD formats SMPTE 274 SMPTE296 SMPTE372 SMPTE 424M 3G SDI Note 3...

Page 12: ...ls at 2kHz HDMI DVI color Auto RGB RGB ext YCbCr 601 YCbCr 601 ext YCbCr 709 YCbCr 709 ext HDMI DVI input color setting Auto Usually RGB Ext designates extended color range full bandwidth as opposed to limiting the color spectrum to comply with ITU standards Default EDID 720p 50 720p 60 1080i 25 1080i 30 1080p 50 1080p 60 WUXGA 50 WUXGA 60 Default EDID setting When you feed a signal to the HDMI in...

Page 13: ... ext YCbCr 709 YCbCr 709 ext XYZ Set the SDI output color mode Auto 601 SD 709 HD RGB 2K Ext designates extended color range full bandwidth as opposed to limiting the color spectrum to comply with ITU standards Note XYZ Colorspace is non linear SDI Resolution NTSC PAL 720p 1080i sf 1080p 2Kp 2Kp Flat Match Input Set the SDI output pixel resolution Match Input In this mode the SDI output will have ...

Page 14: ...te e g Input 1080p 30 Output 1080p 60 SDI Force Interl Off On Force the SDI output to interlaced or Segmented Frame Ancillary out Off Bypass SDI Set the Ancillary data on the SDI output Off No VANC on SDI output Bypass SDI Pass Ancillary data from HDMI input to SDI output Time Code Off Bypass SDI Free wheel Set the embedded SDI output Time code mode Off No embedded timecode on SDI output Bypass SD...

Page 15: ...arameters Sub Menu Value Description Brightness 0 to 100 Brightness value setting Contrast 0 to 100 Contrast value setting Scaling Aspect Ratio Fill Aspect Fit H Aspect Fit V One to One Scaling value setting Aspect Ratio Maintain input aspect ratio Fill Scale to fill the output resolution Aspect Fit H V Scale Horizontally Vertically to fill the output resolution One to One No Scaling De interlacin...

Page 16: ...put Gamma correction For User Defined Input LUT use the DUIS software see Section 5 4 3 Output LUT User Defined 0 1 to 4 0 Set the output Gamma correction For User Defined Output LUT use the DUIS software see Section 5 4 3 H2S OM 001539 DRM Page 16 Version 1 3 Doremi Labs ...

Page 17: ...parameters Sub Menu Value Description Input HDMI DVI Extern Extern Sync is derived from the Sync Input connector H offset X pixels Horizontal Sync offset in pixels V offset X lines Vertical Sync offset in lines H2S OM 001539 DRM Page 17 Version 1 3 Doremi Labs ...

Page 18: ...t on channel 3 SDI Out Groups Auto 1 1 2 1 2 3 1 2 3 4 Off Set the embedded SDI active audio groups Auto All audio inputs will be present on the SDI output Each group has 4 audio channels when 1 2 3 4 is selected all 16 audio channels will be present Off No embedded audio on SDI output 3 5 1 Supported Audio Sample Rates HDMI Input 48 kHz SDI Output 48 kHz Note The H2S 30 does not support audio sam...

Page 19: ...timecode I O status and audio levels when the OSD is not active Off TC BIW Input Status Output Status Burn In Window and Status display Off BIW and Status not displayed TC BIW Timecode is shown in a burn in window on the H2S 30 output Input Status In addition to the timecode BIW the H2S 30 output will display the Input Status including Audio levels Closed Caption presence Input Format and CRC erro...

Page 20: ...dby Auto Standby mode Sets the idle time duration before the unit goes in power down mode automatically IR Infra Red To avoid IR interference with multiple H2S 30 units assign each a different IR code from 0x0 to 0xF 16 total default is 0 Set the DIP switch on the Doremi IR remote accordingly The IR channel can also be set to OFF which disables the IR remote control completely 3 8 Status Menu The ...

Page 21: ...rview Figure 4 Infrared Remote Controller The remote controller is divided into four different areas Input Source Setting Navigation or Menu System HDMI DVI Output Format unused with H2S 30 SDI Output Format H2S OM 001539 DRM Page 21 Version 1 3 Doremi Labs Select Button Menu Button Menu Field Left Arrow Button Up Arrow Button Right Arrow Button Down Arrow Button Exit Button Input Source Setting A...

Page 22: ...080i 1080p InRes SDI Resolution Match Input InFps SDI Frequency Match Input More formats are available through the menu system Up Arrow button Unused Down Arrow button Unused Left Arrow button Navigate OSD left Right Arrow button Navigate OSD right Select button Ok Select Scaling Cycles through the image settings De Int Filter Cycles through the available De int Filter settings Status OSD Cycles t...

Page 23: ...channels of audio at different frequencies see Figure 5 Note The SDI and DVI A buttons are unused 4 3 1 SDI Output Format To set the Output Format to a specific SDI format press OUT SDI on the IR controller Then press the Output format to set 480i 576i 720p 1080i 1080p InRes InFPS more formats are available through the menu system See Figure 6 below for more information Figure 6 Quick SDI Output F...

Page 24: ...annel to the desired setting between the hex values 0x0 and 0xF Remove the battery cover on the rear of the IR remote and set the four dip switches below the battery bay to the corresponding value Note The 4 dip switches represent the binary values 1 2 4 8 from left to right Example If using IR channel 6 set the dip switches 2 and 3 to the high position Figure 7 IR Channel Dip Switches Figure 8 IR...

Page 25: ...nterface_Software 4 2 2 0 exe which can be downloaded from http www doremilabs com After the installation is over the Found New Hardware Wizard will appear Note For Windows 7 users the Found New Hardware Wizard will not appear Go through all the steps shown below Select the No not this time option and then click Next see Figure 9 Figure 9 Found New Hardware Wizard Window Step 1 When asked for the ...

Page 26: ...n the Finish button see Figure 11 Figure 11 Found New Hardware Wizard Window Last Step Run the DUIS and verify that there is a proper connection If the Hardware Installation warning window appears click on the Continue Anyway button see Figure 12 13 H2S OM 001539 DRM Page 26 Version 1 3 Doremi Labs ...

Page 27: ...Figure 12 Hardware Installation Warning Window Figure 13 Hardware Installation Warning Window for Windows 7 H2S OM 001539 DRM Page 27 Version 1 3 Doremi Labs ...

Page 28: ...nits are visible see Figure 14 The Information field located just below the Devices field provides information about the input output current timecode and the audio input level of the connected H2S 30 device see Figure 14 The Control field located below the Information field has tabs that can be used to view or modify various settings on the connected H2S 30 unit These settings include Input Outpu...

Page 29: ...ename into the Settings text box in the top left corner and then click on the Save button The saved settings file will appear in the Settings field Figure 15 H2S 30 Control Panel Window Settings Field H2S OM 001539 DRM Page 29 Version 1 3 Doremi Labs Settings Text Box Settings Field Load Button Save Button Delete Button Import Button Export Button Update Button ...

Page 30: ...art of the window To apply the settings to the connected H2S 30 unit select the file and click on the Load button The H2S 30 settings will be updated see Figure 15 To delete a settings file present in the Settings field select it and click on the Delete button see Figure 15 To update the Settings field to reflect the content of the User Settings folder of the H2S 30 Control Panel application folde...

Page 31: ...bove All parameters are explained earlier in this manual in Section 3 1 5 4 2 Output Tab The Output tab is illustrated below in Figure 16 Figure 16 H2S 30 Control Panel Output Tab All parameters are explained earlier in this manual in Section 3 2 H2S OM 001539 DRM Page 31 Version 1 3 Doremi Labs ...

Page 32: ...n and then press the Gamma Curves button From the Gamma Correction pop up window see Figure 18 you can adjust the Gamma Curves by Formula by adjusting the slider bars in the Formula Editing section or by loading a file To load a file select the File radio button in the Gamma Curves Source section then press the All Colors LUT button and browse for the appropriate file H2S OM 001539 DRM Page 32 Ver...

Page 33: ...Figure 18 Gamma Correction Pop Up Window H2S OM 001539 DRM Page 33 Version 1 3 Doremi Labs Formula Editing Section Load File Radio Button ...

Page 34: ... Tab The Sync I O tab is illustrated below in Figure 19 Figure 19 H2S 30 Control Panel Sync I O Tab All parameters are explained earlier in this manual in Section 3 4 H2S OM 001539 DRM Page 34 Version 1 3 Doremi Labs ...

Page 35: ...o Tab The Audio tab is illustrated below in Figure 20 Figure 20 H2S 30 Control Panel Audio Tab All parameters are explained earlier in this manual in Section 3 5 H2S OM 001539 DRM Page 35 Version 1 3 Doremi Labs ...

Page 36: ...SD Tab The OSD tab is illustrated below in Figure 21 Figure 21 H2S 30 Control Panel OSD Tab All parameters are explained earlier in this manual in Section 3 6 H2S OM 001539 DRM Page 36 Version 1 3 Doremi Labs ...

Page 37: ...gure 22 To enter a new license number click on the Enter New License Number button and type the new license number in the pop up window see Figure 22 To perform a firmware upgrade click on the Firmware upgrade Current 1 6 0 button note that this button provides the current firmware version installed on the connected unit after Current See Section 6 1 for detailed upgrade steps to follow see Figure...

Page 38: ... A window containing the logs will appear Figure 23 Log Window Select Auto Update from the Log Window to see all messages see Figure 23 H2S OM 001539 DRM Page 38 Version 1 3 Doremi Labs ...

Page 39: ...are as presented in Section 5 4 7 To perform an update via USB follow the steps below Connect the H2S 30 to the computer using the USB cable provided with the unit Start the Doremi Universal Interface Software See Section 5 for more information Go to the System tab see Section 5 4 7 Click on the Firmware upgrade button Click the Browse button and select the firmware file e g ghx_1 6 0 bin and then...

Page 40: ...igital Visual Interface HDMI High Definition Multimedia Interface HD SDI High Definition Serial Digital Interface IR Infra Red OSD On Screen Display PAR Pixel Aspect Ratio SDI Serial Digital Interface USB Universal Serial Bus H2S OM 001539 DRM Page 40 Version 1 3 Doremi Labs ...

Page 41: ...cription 02 10 2011 1 0 First version 03 02 2011 1 1 New pictures added 07 26 2012 1 2 Logo and contact information updated 02 13 2013 1 3 Minor revisions made to entire document Section 1 updated H2S OM 001539 DRM Page 41 Version 1 3 Doremi Labs ...

Reviews: