8
FnC 05
Filter Settings (non approval only)
Zero: 0-9
(default 0)
FiL: 0-9
(default 0)
3db: 0-9
(default 5)
Adjustments to offset environmental weighing interferences
Press TARE to enter sequence
1.
ZEro
“Weight Noise Threshold” eliminates minor
weighing
noise
when weight on scale is over 1/3 full capacity: 0=off;
1-9 = 1d to 9d threshold (weighing fluctuation below this
threshold is de-noised).
2.
FiL
“Weighing Sampling Period” sets time period for scale
to gather weighing information: 0 is shortest, fastest, & least
stable. 9 is longest, slowest, & most stable.
3.
3db
“Weighing Bandwidth” sets frequency range for
gathering weighing information: Select 0-9. Default is 5. 0
is lowest, slowest, & most stable; 9 is highest, fastest, &
least stable.
FnC 06
Hold Function (non approval only)
hoLd
0: Disabled (default)
1: Peak Hold Mode
2: Hold on stable weight, cleared by pressing any key
3: Hold on stable weight, cleared when weight removed
FnC 08
Two Weighing Units Setting
uSEr
This setting allows the use of only two units (instead of four)
for quick unit switching.
0: Disabled (lb, kg, g, oz available)
1: kg (lb, kg available)
2: g (lb, g available)
3: oz (lb, oz available)
FnC 09
Tare on Demand (non approval only)
St
0: Disabled
1: Tare enabled when in motion