OP000530
4-83
Inspection, Maintenance and Adjustment
1.
Remove strainer cap (4, Figure 151) from strainer (3) on
end of inlet hose (5).
NOTE:
Keep strainer cap (4
) in a safe
location to reseal strainer (3) after refueling is
complete.
2.
Insert inlet hose (5, Figure 151) into refueling tank.
3.
Turn fuel pump switch (Figure 152) inside of battery box on
front side to "I" (ON) position.
NOTE:
Transfer pump rate of flow is approximately 35
liters/minute (9.24 U.S. gpm). Use extra care
not to overfill fuel tank so that fuel does not over
flow.
4.
Once fuel transfer is completed, immediately turn switch to
"O" (OFF) position to stop pump.
5.
Lift inlet hose (5, Figure 151) from fueling source and turn
switch to "I" (ON) position for two - three seconds to drain
remaining fuel from hose to fuel tank.
6.
Install strainer cap (4, Figure 151) on inlet strainer (3) and
return hose (5) to storage position.
FG006783
Figure 152