OP000599
4-47
Inspection, Maintenance and Adjustment
Change Pilot Filter
NOTE:
Change pilot filter after first 250 hours of operation or
rebuild, and every 1,000 hours thereafter.
NOTE:
If pilot filter clogged warning light (Figure 78) on
instrument panel comes "ON" the pilot filter must be
serviced.
1.
Position the machine on firm, level ground. Lower the front
attachment to the ground and shut down engine.
2.
Loosen the breather cap (1, Figure 76) slightly to release
the internal pressure.
3.
Locate pilot system filter assembly. See Figure 79.
4.
Unscrew canister (5, Figure 80) and remove O-ring (3) and
filter cartridge (4).
NOTE:
The canister will be filled with oil. Use caution
when removing this assembly.
5.
Insert a new filter cartridge and O-ring. Apply a small
amount of oil around the entire O-ring and install the
canister assembly onto the filter head (1, Figure 80).
NOTE:
Used filter should always be disposed of
according to local regulations.
6.
After changing pilot filter, vent air from pump and check
level of hydraulic oil tank.
Figure 78
C
H
C
E
F
H
E/G SPEED
1700
RPM
FG000763
02/05 [MO] 11:30
Figure 79
P
1
OUT
IN
FG006317
WARNING!
The hydraulic oil will be hot after normal machine
operation.
Allow the system to cool down before changing pilot filter.
Figure 80
FG000323
2
1
3
4
5
Summary of Contents for DX140LC
Page 2: ......
Page 67: ...OP000597 2 3 Operating Controls ...
Page 87: ...OP000597 2 23 Operating Controls ...
Page 122: ...OP000597 Operating Controls 2 58 CD Player Optional AST DIR FG000109 Figure 123 ...
Page 184: ...OP000598 Operation 3 48 ...
Page 193: ...OP000599 4 9 Inspection Maintenance and Adjustment ...
Page 272: ...OP000599 Inspection Maintenance and Adjustment 4 88 ...
Page 278: ...OP000600 Transportation 5 6 ...
Page 284: ...OP000013 Troubleshooting 6 6 ...
Page 292: ...OP000601 Specification 7 8 ...