OPTIONS
45
7/26E, 7/31E, 7/41
SAFETY
Refer to the SAFETY SECTION in this manual.
GENERAL INFORMATION (6,5 kVA - 7/26E, 7/31E, 7/41)
Rated output
4,8 kW @ 0,8 Power factor
(PF) lagging
Rated voltage
110V 1ph or 230V 1ph or 230V 3ph or
400V 3ph + 230V 1ph @ 3000 revs
min-1
Voltage regulation
+/- 6%
Maximum continuous output
6 kVA @ 0,8 PF
Rotor type
Brushless
(110/230V 1ph)
Rotor type
Rotating armature with sliprings
(230V 3ph / 400V 3ph + 230V 1ph)
De-rating factors at 0.8 pf continuous load:
Air in temp 20°C
Continuous
Air in temp 30°C
5,7 KVA @ 0.8 p.f continuous
Air in temp 46°C
4,5 KVA @ 0.8 p.f continuous
De-rating factors for intermittent load:
Air in temp 20-35°C,55 mins/hr @ 0.8, 5 mins off load
Air in temp 35-40°C,50 mins/hr @ 0.8, 10 mins off load
Air in temp 40°C + ,45 mins/hr @ 0.8, 15 mins off load
Socket outlets:
110V 1ph & 230V 1ph
1 x 32 amperes
2 x 16 amperes
230V 3ph
1 x 16 amperes
400V 3ph + 230V 1ph
400V 3ph = 1 x 16 amperes
230V 1ph = 2 x 16 amperes
GENERAL INFORMATION (8,5 kVA - 7/31E, 7/41)
Rated output
6,8 kW @ 0,8 Power factor
(PF) lagging
Rated voltage
110V 1ph or 230V 1ph or 230V 3ph or
400V 3ph + 230V 1ph @ 3000 revs
min-1
Voltage regulation
+/- 6%
Maximum continuous output
8,5 kVA @ 0,8 PF
Rotor type
Brushless
(110/230V 1ph)
Rotor type
Rotating armature with sliprings
(230V 3ph / 400V 3ph + 230V 1ph)
De-rating factors at 0.8 pf continuous load:
Air in temp 20°C
Continuous
Air in temp 30°C
8,1 KVA @ 0.8 p.f continuous
Air in temp 46°C
6,4 KVA @ 0.8 p.f continuous
De-rating factors for intermittent load:
Air in temp 20-35°C,55 mins/hr @ 0.8, 5 mins off load
Air in temp 35-40°C,50 mins/hr @ 0.8, 10 mins off load
Air in temp 40°C + ,45 mins/hr @ 0.8, 15 mins off load
Socket outlets:
110V 1ph & 230V 1ph
1 x 32 amperes
2 x 16 amperes
230V 3ph
1 x 16 amperes
400V 3ph + 230V 1ph
400V 3ph = 1 x 16 amperes
230V 1ph = 2 x 16 amperes
Earth leakage protection is provided by a single residual current
device. Miniature circuit breakers (MCB) are fitted to provide both
overcurrent and short circuit protection for the generator.
Each socket outlet is protected by a spring loaded weather–proof
cover.
OPTION - GENERATOR
Summary of Contents for 7/26E
Page 3: ......
Page 4: ......
Page 17: ...GENERAL INFORMATION 13 7 26E 7 31E 7 41 7 26E 7 31E SHIPPING SKID 7 41 PERMANENT SKID...
Page 38: ...34 ELECTRICAL SYSTEM 7 26E 7 31E 7 41 7 41...
Page 54: ...50 OPTIONS 7 26E 7 31E 7 41 A C Electrical Power Schematic Diagram 7 26E 110V 6kVA...
Page 55: ...OPTIONS 51 7 26E 7 31E 7 41 A C Electrical Power Schematic Diagram 7 31E 7 41 110V 8 5kVA...
Page 56: ...52 OPTIONS 7 26E 7 31E 7 41 A C Electrical Power Schematic Diagram 7 26E 7 31E 7 41 230V 6kVA...
Page 57: ...OPTIONS 53 7 26E 7 31E 7 41 A C Electrical Power Schematic Diagram 7 26E 7 31E 7 41 400 230V...
Page 88: ......
Page 89: ......
Page 90: ...Doosan Bobcat EMEA s r o U Kodetky 1810 263 12 Dob Czech Republic www doosanportablepower eu...