Powering Up Cellular System -
The Voice ONLY cellular system will
NOT
function until
online registration
has been successfully completed on DoorKing’s Cellular
website. Within 1 minute of powering up the cellular module, the module lights should turn on. If they don’t, check that the cellular power switch is turned ON. Signal
strength Bars should be lit
GREEN
indicating good cell reception.
YELLOW
bars indicates poor reception but may still work.
RED
bars indicates no reception. The
cellular module’s lithium battery needs time to charge. Allow at least ½ hour of charging time before using system.
Program the assigned phone number (from DKS
cellular registration) into the 1800 entry system to make a test call.
Adjusting 1800 Entry System -
When making a test call from the 1800
telephone entry system
,
adjust the microphone, speaker and feedback on the entry system,
See
specific 1800 Installation/Owner’s instruction manual for more information.
Using Two 1800 Entry Systems -
Each 1800 must be programmed for
MULTIPLE SYSTEMS
.
see specific 1800 Installation/Owner’s instruction manual for informa-
tion to program each 1800.
TWO 1800 Entry Systems Master Codes -
Each 1800 entry system’s Master Code must be
DIFFERENT
. The DKS cellular server identifies each 1800 by its unique
master code. This allows separate programming for each 1800.
Cellular System Information
DKS Cellular requires a
SEPARATE
registration from the DKS IM Server. If a customer already has an IM Server account and wants to add a DKS Cellular system, this
will require a
SEPARATE
User ID and Registration.
•
DKS IM Server includes:
IM Server Modem
and
IM Server Client
.
•
DKS Cellular includes:
Cellular Phone
and
Data Transfer
.
Before registering a cellular system on DoorKing’s Cellular Server you will need:
•
SIM ID
number located on the cellular module (number is unique for each cellular module).
•
Master Code of
System A
.
•
Master Code of
System B
if connected,
MUST
be a different master code than System A.
OPTION 1.
Go to DKS cellular website:
https://dksdb.dksoftware.com/NewUserRegChoice.aspx
to register, follow instructions on website.
OPTION 2.
Online registration is directly offered when installing the DoorKing Remote Management Software version 6.3.g or later on YOUR internet connected PC.
Create an account and select the
Voice ONLY
account from the options.
•
Voice Only
(Only service available for
Voice ONLY cellular system
)
•
Voice and Data (not applicable)
•
Data Only (not applicable)
Enter
the
SIM ID
number to identify the
Cellular System
to the account created. After the SIM ID number is entered along with the local billing address,
a local cellular phone number will be assigned
to that cellular device.
Register the 1800 systems (Master Codes) to the account. The
FIRST 1800 master code
entered will be identified as
System A
. If a second 1800 master code
is entered, it will be identified as
System B
.
Online Registration MUST be Completed
Testing
Final Testing after the Cellular System has been Registered -
All systems should be tested and final
adjustments done. Connect a telephone butt set to the cellular system circuit board
Phone Line
and make sure the line is
active and that phone calls may be made and received.
If the phone line is not active, something went wrong during the registration which must be corrected. If still having
problems, call DoorKing tech support. Attach a label to the inside of the cellular enclosure listing the local phone number that
was assigned during registration.
PH LINE
SYSTEM A
PH LINE
DATA OUT
RS 232
BUSY OUT
BUSY IN
GROUND
DATA IN
Voice Testing -
Program a phone number into the memory of the 1800 using the 1800 keypad. Then call that programmed number on the 1800. Have the call
recipient press “9” on their phone to open the door. Verify the 9 tone is detected (door will open). The feedback on the 1800
MUST
be adjusted for the cellular
network. This adjustment is
VERY
important for DTMF detection. See specific 1800 Installation/Owner’s instruction manual for programming and adjustment
information. Note: The 1812 Plus
automatically
adjusts feedback and needs no adjustment.
IMPORTANT Note:
Factory set
Tone Open
numbers:
“9”
TONE activates Relay 1.
“0”
TONE activates Relay 0.
“5”
TONE activates Relay 2.
For cellular, change the tone open number for Relay 2 to
“8”
TONE. Leave Relay 1 and Relay 0 tone open numbers the same.
4
1801-065 Issued 1-19
Version B