3
1800-065 Issued 1-19
Version D
PH LINE
16VAC
16VAC
E GND
POWER
POWER
SOURCE
SYSTEM A
PROGRAM
MASTER
CODE
NORMAL
DATA
RESET
LINK
SYSTEM B
ON/OFF
Button
Ethernet
1800-010
PH LINE
DATA OUT
BUSY OUT
BUSY IN
GROUND
DATA IN
DATA OUT
RS 232
RS 232
BUSY OUT
BUSY IN
GROUND
DATA IN
PH LINE
PH LINE
NC
NO
RING
HF
1816
HS
ON
SPK
VOL
FEED
BACK
RS 232
ELEVATOR
OFF
KEYPAD
3 2 1
3
3
2
1
MASTER
CODE
16AC
16AC
BAT
1NO
1NC
1C
2RY
2C
A
Z
IMC
5VDC
IMD
SPKR
COM
MIC
PSW
CGND
PHONE
1
2
3
1
2
3
4
5
6
7
8
9
10
111
21
3
14
1
2
3
4
5
6
NC
NO
RING
HF
1816
HS
ON
SPK
VOL
FEED
BACK
RS 232
ELEVATOR
MIC
VOL
OFF
KEYPAD
3 2 1
3 2 1
3
2
1
MASTER
CODE
16AC
16AC
BAT
1NO
1NC
1C
2RY
2C
A
Z
IMC
5VDC
IMD
SPKR
COM
MIC
PSW
CGND
PHONE
1
2
3
12
34
5
6
7
8
9
10
11
12
13
14
1
2
3
4
5
6
SYSTEM A
1830
Voice/Data cellular system
should be as close as
possible to
SYSTEM A
.
SYSTEM B
Optional 1830
Main Terminal
Twisted Pair
MUST
be used.
Twisted Pair Phone
Line
MUST
be used.
500 ft RS 232 MAX
500 ft RS 232 MAX
DATA OUT-Red
DATA IN-Black
BUSY OUT-White
BUSY IN-Brown
GROUND-Green
RS 232 Connection
1
2
3
4
5
System A
Terminal
1830
Terminal
Supplied Power
Transformer
Earth
Ground
Voice/Data Cellular System
Data
Voice
Voice
Data
DKS Cellular Server
hosted by AT&T cellular network
with DKS Online Registration Completed
Wiring
Power
Icon
Signal
Strength
Bars
SIM
Status
Not Used
Program
Slide
Switch
Master
Code
Button
Ethernet
Data/Link
LEDs
RJ45
Cable
Cellular Module
TWO Entry Systems -
The Voice/Data
cellular system can supply telephone
service and programming for
TWO 1830s
designated as
System A
and
System B
.
The telephone line is
SHARED
with both
1830s. Each 1830
MUST
be programmed
for
Multiple Systems
, see specific 1830
Installation/Owner’s instruction manual
for more information.
RS 232
RS 232
RS 232
“A”
RS 232
“A” LEDs
External
Antenna
Connection
RS 232
“B” LEDs
Cellular Power
Phone Jack
Board
Power
LED
RS 232
“B”
The
EARTH GROUND
must be connected to a proper
ground close by (ground rod, cold water pipe in the
ground, existing electrical ground, etc.).
Note: Older 1830 series circuit boards
can be updated
to Rev W or higher for better DTMF tone distortion.
CELLULAR MODULE LEDs:
Signal Strength Bars:
Green - More bars, more signal strength.
Bars only display when call is being made.
SIM Status
- Red blinking (error, usually NO SIM)
POWER Icon
- ON (has power)
1816
Jumper
MUST
be
Moved
1816
Jumper
MUST
be
Moved
Do Not Connect Power
To A Receptacle
Controlled By
A
ON/OFF Switch.
System B Phone Line Alternate Use -
If system B is
NOT
being used for a
second phone entry system, a phone can be installed and used. It shares the
phone line with the System A phone entry system. The phone
CANNOT
be
used while a transaction is taking place on System A.
16.5VAC
40 VA
DATA OUT-Red
DATA IN-Black
BUSY OUT-White
BUSY IN-Brown
GROUND-Green
RS 232 Connection
1
2
3
4
5
System B
Terminal
1830
Terminal
LED on Enclosure Door
“AC power
ON
” indicator
Type of wiring to be used on ALL external devices:
A)
Type
CL2
,
CL2P
,
CL2R
, or
CL2X
.
B)
Other cable with
equivalent
or
better
electrical,
mechanical, and flammability ratings.
Wiring methods used shall be in accordance
with National Electrical Code, ANSI/NFPA 70.
Permissible wire sizes for the terminals (12-26 AWG).