This manual describes installation of DoorHan industrial sectional door of
ISD ThermalPRO series with standard component parts.
This manual contains important safety, installation and maintenance
instructions. Please keep this manual for future reference.
If you should require any assistance or additional information, please
contact DoorHan service department (ref. «Service department» paragraph).
GENERAL INSTALLATION INSTRUCTIONS
Only the component parts specified and supplied with the door
should be used.
Do not permit children to be around the door during its installation.
Follow the instructions provided with the electric operator during
its installation.
Before starting door installation make sure the door opening is
properly prepared and suitable for installation.
The door opening shall always be free of any foreign objects.
Calculation and connection of the heating circuit, supply cable
and cable between boxes is performed by the door installer.
INSTALLATION TEAM
The optimal number of installation team — 2 people. If the door is to be equipped
with an operator or a heating circuit the team should include a qualified electrician.
Estimated time of door assembly is 3,5 hours.
Door installation shall be performed by a team which have been trained at
DoorHan training centre and got a corresponding certificate.
The team should use proper tools specified at page 3.
INSTALLATION REQUIREMENTS
The guides must be installed vertically, which can be checked by a water level.
Diagonals of horizontal tracks shall be equal (allowable deviation is ± 5 mm).
Connect the door parts strictly following installation instructions.
Side seals and gaskets of the panel shall be strictly in line, gaps are not allowed.
Spring tensioning shall be performed with a special tap wrench (ref. page 17,
fig. 13,1a, 13.1b).
The spring is tensioned for a particular number of turns (ref. page 16, fig. N).
Fasten the spring end with a bolt applying force of maximum 15 N·m.
After spring tensioning please verify that the split pin (ref. page 17, fig.13.3a,
13.3b) is removed from the spring break safety device.
Mounting options:
а) if the wall around the opening is strong enough to support the door (whole
brick, solid concrete, metal channels) it can be attached directly to the wall;
b) if the wall material has low strength (hollow brick, silicate block, low
compressive strength concrete, wood, etc.), then it is required to frame the opening
with steel profiles.
Before installation, please ensure that the content of your door kit is complete
as per the specification included in the package.
HEATING CABLE SPECIFICATIONS
Input voltage — 220 V.
Power per 1 m — 30 W.
Operating temperature: -60…+200 °С (up to +230 °С for a short time).
Minimum bending diameter: 15 mm.
RESPONSIBILITY FOR INSTALLATION
DoorHan does not directly control the installation, maintenance and operation of
a sectional door and is not responsible for the safety and quality of the installation.
The contents of this manual can not serve as the basis for submitting any
complaints to the manufacturer.
The installation company is held responsible for the quality of sectional door
installation.
DoorHan reserves the right to introduce any changes to this manual without any
prior notice to the customer.
DOOR OPERATION
Door shall be lifted and lowered with ease.
Door leaf shoulld be properly balanced: it shall not spontaneously lower or lift.
For opening the door in manual operation use only the door handle.
Door can only be locked with a special latch or mechanical lock.
Keep the door operating area clear of children, animals and foreign objects.
EMERGENCY SITUATIONS
In case of door failure never perform repair works by yourself. We recommend
to call the service department.
In case a safety device was actuated please verify that nobody was injured. Call
the service department.
If the door opens with a difficulty make sure that all door components are in
good working order and then adjust. If there are any damaged components please
call the service department.
SERVICE DEPARTMENT
Should you require any assistance or additional information please contact the
service department at the following addresses:
а) [email protected],
b) at the address of product purchase.
You can contact your dealer on any question arising during door operation. For
addresses and phone numbers see the Contract.
SAFETY INSTRUCTIONS
If the heating circuit is to be installed please do the following:
1. Pre-installation verification.
1.1. Make sure the quantity and numbers of the heating cable and its
components correspond to the data listed in the installation chart.
1.2. Verify that the heating cable and its components were not damaged
during transportation.
1.3. Verify that the rated supply voltage of the heating cable corresponds to
the supplied operating voltage.
2. Heating cable installation.
2.1. When installing the cable, avoid sudden jerks and excessive force, as
well as walking on the cable and passing it over with a vehicle. If the heating cable is
left at the installation site for some time, it must be protected from moisture.
ATTENTION!
In case of failure or incorrect operation of the heating cable, upon detection of
smoke or unusual odour it is required to contact the service department.
WARNING!
As with any electrical equipment operating from high voltage, damage to the
heating cable and heating components or improper installation can lead to moisture
penetration into the system or its contamination, which can result in short circuit,
sparking and fire outbreak.
Do not connect heating cable conductors to each other as it will cause short
circuit. All unconnected heating cable ends must be insulated with cable end sealing.
To prevent fire or explosion in hazardous areas, ensure that the maximum
temperature of the heating cable sheath is below the self-ignition temperature of the
gases in the hazardous area. Heating system installation shall be performed using
only corresponding spare parts with observation of installation instructions attached
to them.
Heating circuit installation can be performed by personnel:
- trained and certified for basic fire safety;
- having at least the first qualification group on electrical safety;
- qualified in electrical safety instructions;
- having knowledge of first aid for burns and electric shock.
GENERAL INFORMATION
Summary of Contents for THERMALPRO Series
Page 4: ...4 S DOOR COMPONENT PARTS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 17 18 S 16...
Page 5: ...5 DOOR COMPONENT PARTS 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 S S S S...
Page 9: ...9 S 10 mm S 14 3 S 3 13 S 5 1 2 mm 5 13 27 B 4 4a 4 1b 4 2b 4 2b 3 1b 3 2b DOOR INSTALLATION...
Page 15: ...15 11 _ 11b 19 19 17 17 17 19 32 18 A C 19 26 11 11 1 11 2a 11 3 11b 10 mm DOOR INSTALLATION...
Page 19: ...19 16 16 1 16 2 30 30 30 30 C 10 mm 16 3 DOOR INSTALLATION...
Page 21: ...21 NOTES...
Page 22: ...22 NOTES...
Page 23: ...23 NOTES...