background image

1. DEsCrIPTIOn

Photoelectric detector Photocel is a safety device, consisting of infrared 

transmitter and receiver, which are installed in a gate opening. If an infrared 
beam is interrupted, the control board receives the signal of an obstacle in a 
dangerous area of an automatic system operation, and a system reacts as it 
was preset by the operation logic - stop or reverse of gates.

2. IMPOrTAnT nOTICE

• 

Warning!

 In order to ensure personal safety, it is important that all 

instructions be carried out to the letter. Incorrect installation or use of 
product could cause serious personal injury.
•  Before  attempting  installation,  read  the  instructions  carefully  and 
store in a safe place for future reference.

3. InsTALLATIOn

Installation  at  height  more  than  20  sm,  but  more  2  m.  Photo  cells  is 

recommended it is necessary to instal vertically and in a parallel way each 
other. The first instal and connects the receiver, after the TX is connected. 
Move  a  TX  in  the  field  of  installation  while  photo  cells  do  not  become 
parallel each other. The lamp of turn off of the receiver thus will go out, 
then fix a radiator. Installation is completed.

Attention! 

From  for  features  of  distribution  of  infra-red  radiation 

incorrect system operation is possible at small distance between a trans-
mitter  and  the  receiver.  The  distance  between  them  should  be  not  less 
than 1 m. If sensitivity of the receiver at small distance between a trans-
mitter and the receiver is insufficient, remove a receiver lens to increase 
its sensitivity.

4. COnnECTIOns

Select a necessary operating mode of photo cells concerning control-

ling contacts: NO (it is normal opened) or NC (normally closed). If neces-
sary change position of crosspiece NC/NO.

*25  m  supposed  for  stable  work  the  distance  can  be  reduced  by  30%  with  bad 

weather conditions: fog, rain, dust, etc.

Avoid ultraviolet beams!

Technology

Infrared

Working distance*

 

Up to 40 m

Supply voltage

24 V AC/DC

Wave length

940 nm

Current consumption

RX-40mA 
TX-50mA

Angle tolerance 

< ± 10°

Operating temperature

 

-20°С до 70°С

Relay output

1А макс 30V

Dimension

49,8х75,6х29 мм

EC DECLArATIOn OF COnFOrMITY

We: DoorHan Europe s.r.o.
Bozeny Nemcove 1689, 43201 Kadan, Ceska Respublika
Herewith declare under sole responsibility that:
The active optoelectronic safety device model PHOTOCELL

• Declares that:
 The active optoelectronic safety device model PHOTOCELL
• complies with the essential safety requirements of the following di-
rectives :
 73/23/EEC and subsequent amendment 93/68/EEC
 89/336/EEC and subsequent amendment 92/31/EEC and 93/68/EEC

Additional note:

These products have undergone tests in a typical uniform configuration 
(all products manufactured by DoorHan Europe s.r.o.)
01/03/2010                       Mikhail Kiselev                          Managing Director
Date signature

InsTALLATIOn MAnUAL 

PHOTOCELL

 

18

40

11

0

LED3

G

N

D

V

C

C

 

(+

24

)

C

O

N

2

LE

D

2

G

N

D

VCC 

(+24

)

C

O

N

1

LE

D

1

IR

C

O

M

NO

NC

Управляющие 

контакты

 

Питание  24 В AC/DC

NO/NC перемычка

LED Индикатор

Линза

Operating output

Power supply 
24 V AC/DC

NO/NC Jumper 

LED Indicator 

Lens

DOORHAN

 

18

40

11

0

LED3

G

N

D

V

C

C

 

(+

24

)

C

O

N

2

LE

D

2

G

N

D

VCC 

(+24

)

C

O

N

1

LE

D

1

IR

C

O

M

NO

NC

 

DOORHAN

 

18

40

11

0

LED3

G

N

D

V

C

C

 

(+

24

)

C

O

N

2

LE

D

2

G

N

D

VCC 

(+24

)

C

O

N

1

LE

D

1

IR

C

O

M

NO

NC

Управляющие 

контакты

 

Питание  24 В AC/DC

NO/NC перемычка

LED Индикатор

Линза

Operating output

Power supply 
24 V AC/DC

NO/NC Jumper 

LED Indicator 

Lens

DOORHAN

 

18

40

11

0

LED3

G

N

D

V

C

C

 

(+

24

)

C

O

N

2

LE

D

2

G

N

D

VCC 

(+24

)

C

O

N

1

LE

D

1

IR

C

O

M

NO

NC

 

DOORHAN

Reviews: