background image

1. DEscrIPTIOn

Photoelectric detector Photo - W is a safety device, consisting of infrared 

transmitter and receiver, which are installed in a gate opening. If an infrared 
beam is interrupted, the control board receives the signal of an obstacle in a 
dangerous area of an automatic system operation, and a system reacts as it 
was preset by the operation logic - stop or reverse of gates.

2. IMPOrTAnT nOTIcE

• 

Warning!

 In order to ensure personal safety, it is important that all in-

structions be carried out to the letter. Incorrect installation or use of prod-
uct could cause serious personal injury.
• Before attempting installation, read the instructions carefully and store 
in a safe place for future reference.

3. InsTAllATIOn

Installation at height more than 20 sm, but not more 2 m. The first instal 

and connects the receiver, after the TX is connected. Move a TX in the field 
of installation while photo cells do not become parallel each other. In this case 
the indicator LED3 of the receiver will evenly light up. Installation is completed.

notes

1. When the distance between the photocells is less than 5 meters, then it is 

necessary to remove the jumper JP1 on the transmitter.

2. You should remove a battery, if the transmitter is connected by means 

of wires.

Attention! 

From for features of distribution of infra-red radiation incor-

rect system operation is possible at small distance between a transmitter and 
the receiver. The distance between them should be not less than 1 m. If sensi-
tivity of the receiver at small distance between a transmitter and the receiver 
is insufficient, remove a receiver lens to increase its sensitivity.

4. cOnnEcTIOns

Select a necessary operating mode of photo cells concerning controlling 

contacts:  NO  (it  is  normal  opened)  or  NC  (normally  closed).  If  necessary 
change position of crosspiece NC/NO.

1. You should switch DIP 1 on SW1 of the transmitter into ON or OFF posi-

tion, and you should switch DIP2 on SW1 into OFF position. When supply volt-
age is connected, LED3 will light up one time per second, and the transmitter 
will send a signal.

2. You should switch DIP 1 on SW1 of the transmitter into ON or OFF po-

sition, and you should switch DIP2 on SW1 into ON position. When supply 
voltage is connected, LED3 will be switched off, and the transmitter will not 
send any signals.

The given logic is selected, when it is necessary to deactivate functioning 

of the photocells.

*25  m  supposed  for  stable  work  the  distance  can  be  reduced  by  30%  with  bad 

weather conditions: fog, rain, dust, etc.

Avoid ultraviolet beams!

Ec DEclArATIOn OF cOnFOrMITY

We: DoorHan Europe s.r.o.
Bozeny Nemcove 1689, 43201 Kadan, Ceska Respublika
Herewith declare under sole responsibility that:
The active optoelectronic safety device model PHOTO - R

• Declares that:
 The active optoelectronic safety device model PHOTO - R
• complies with the essential safety requirements of the following directives :
 73/23/EEC and subsequent amendment 93/68/EEC
 89/336/EEC and subsequent amendment 92/31/EEC and 93/68/EEC

Additional note:

These  products  have  undergone  tests  in  a  typical  uniform  configuration  (all 
products manufactured by DoorHan Europe s.r.o.)
01/03/2010                       Mikhail Kiselev                          Managing Director
Date signature

InsTAllATIOn

MAnUAl 

PHOTO – W

range

12m-20m, the distance can be reduced by 30% with bad 

weather conditions: fog, rain, dust, etc.

Frequency

2.5 KHz

Voltage

12V-24V, DC/AC

Wave length

940mm

Input

Input

Battery

3 В, CR 123 A

Angle tolerance

<+/-5

Operating temperature

-20C ~ 70C

relay output

150mA, max. 27V

Dimension

37.5x108x3 6mm

Output way

NO/NC

Appendix

DIP1

DIP2

SW1

ON

LED3

CON2

JP

1

GND

VCC

(+24)

Lers

LED Indicator
NO/NC Jumper

Operating
output

Power supply 24 V AC/DC