1. DEscrIPTIOn
Photoelectric detector Photo - W is a safety device, consisting of infrared
transmitter and receiver, which are installed in a gate opening. If an infrared
beam is interrupted, the control board receives the signal of an obstacle in a
dangerous area of an automatic system operation, and a system reacts as it
was preset by the operation logic - stop or reverse of gates.
2. IMPOrTAnT nOTIcE
•
Warning!
In order to ensure personal safety, it is important that all in-
structions be carried out to the letter. Incorrect installation or use of prod-
uct could cause serious personal injury.
• Before attempting installation, read the instructions carefully and store
in a safe place for future reference.
3. InsTAllATIOn
Installation at height more than 20 sm, but not more 2 m. The first instal
and connects the receiver, after the TX is connected. Move a TX in the field
of installation while photo cells do not become parallel each other. In this case
the indicator LED3 of the receiver will evenly light up. Installation is completed.
notes
1. When the distance between the photocells is less than 5 meters, then it is
necessary to remove the jumper JP1 on the transmitter.
2. You should remove a battery, if the transmitter is connected by means
of wires.
Attention!
From for features of distribution of infra-red radiation incor-
rect system operation is possible at small distance between a transmitter and
the receiver. The distance between them should be not less than 1 m. If sensi-
tivity of the receiver at small distance between a transmitter and the receiver
is insufficient, remove a receiver lens to increase its sensitivity.
4. cOnnEcTIOns
Select a necessary operating mode of photo cells concerning controlling
contacts: NO (it is normal opened) or NC (normally closed). If necessary
change position of crosspiece NC/NO.
1. You should switch DIP 1 on SW1 of the transmitter into ON or OFF posi-
tion, and you should switch DIP2 on SW1 into OFF position. When supply volt-
age is connected, LED3 will light up one time per second, and the transmitter
will send a signal.
2. You should switch DIP 1 on SW1 of the transmitter into ON or OFF po-
sition, and you should switch DIP2 on SW1 into ON position. When supply
voltage is connected, LED3 will be switched off, and the transmitter will not
send any signals.
The given logic is selected, when it is necessary to deactivate functioning
of the photocells.
*25 m supposed for stable work the distance can be reduced by 30% with bad
weather conditions: fog, rain, dust, etc.
Avoid ultraviolet beams!
Ec DEclArATIOn OF cOnFOrMITY
We: DoorHan Europe s.r.o.
Bozeny Nemcove 1689, 43201 Kadan, Ceska Respublika
Herewith declare under sole responsibility that:
The active optoelectronic safety device model PHOTO - R
• Declares that:
The active optoelectronic safety device model PHOTO - R
• complies with the essential safety requirements of the following directives :
73/23/EEC and subsequent amendment 93/68/EEC
89/336/EEC and subsequent amendment 92/31/EEC and 93/68/EEC
Additional note:
These products have undergone tests in a typical uniform configuration (all
products manufactured by DoorHan Europe s.r.o.)
01/03/2010 Mikhail Kiselev Managing Director
Date signature
InsTAllATIOn
MAnUAl
PHOTO – W
range
12m-20m, the distance can be reduced by 30% with bad
weather conditions: fog, rain, dust, etc.
Frequency
2.5 KHz
Voltage
12V-24V, DC/AC
Wave length
940mm
Input
Input
Battery
3 В, CR 123 A
Angle tolerance
<+/-5
Operating temperature
-20C ~ 70C
relay output
150mA, max. 27V
Dimension
37.5x108x3 6mm
Output way
NO/NC
Appendix
DIP1
DIP2
SW1
ON
LED3
CON2
JP
1
GND
VCC
(+24)
Lers
LED Indicator
NO/NC Jumper
Operating
output