ReMote ContRoLLeR PRoGRAMMInG

2. REMOTE CONTROLLER PROGRAMMING

 

2.1.

   

Cleaning of the receiver’s memory. 

After power is on, hold down the record button for remote controllers (CODE) for 10

seconds. Indicator “A” will be constantly on, warning light will flash, then indicator “B” will be on for one second and go out
to confirm erasing of stored codes, warning light and indicator “A” will go out. 

 

2.2.

   

Record of DoorHan remote controllers in the receiver. 

 To record remote controllers, press and hold down the record button

for remote controllers (CODE) for 3 seconds. Press twice the selected button (you later want to control the drive operation)
within 10 sec when indicator “A” is on. Indicator “B” will flash once and go out to confirm successful record of code of
remote controller in the receiver’s memory, warning light and indicator “A” will go out.

  Note:
  •  

repeat the recording procedure for each new remote controller to set up some remote controllers.

  •  

in case of memory overflow in receiver, indicator “B” will flash three times (maximum number  

 of remote controllers in the receiver’s memory - 60 pcs.)

 

2.3.

 

Remote programming for Doorhan remote controllers.

 

Perform the items 1-4 within 5-second interval:

1. Press and hold down the button 2 (see figure) of programmed remote controller.
2. Without releasing the pressed button 2, press and hold down the button 1.
3. Release the buttons.
4.Press programmed button on the remote controller, the receiver enters the programming mode for remote controllers
(indicator “A” will be constantly on, warning light will flash)

  Note:
  •  

The record of remote controller can be carried out within 10 seconds after entering the programming mode, then receiver 

exits the programming mode. 

5. Press the button (to later control the operation of the receiver channel) twice on new remote controller. Indicator “B” will
flash once and go out to confirm successful record of code of remote controller in the receiver’s memory, warning light and
indicator “A” will go out.

  Note:
  •  

Programming of the remote controllers shall be carried out within the operating range of the drive receiver.

  •  

in case of memory overflow in receiver, indicator “B” will flash three times (maximum number of remote controllers in the   

receiver’s memory - 60 pcs.)

  2.4.  Marking of Doorhan remote controllers buttons

1

2

4

3

2

3

4

1

1

2

2

1

6

Summary of Contents for PCB-SL

Page 1: ...DoorHan 2016 Programming instructions board PCB SL Actual versions pcb v 1 0 soft v 1 0 Content ReMote ContRoLLeR PRoGRAMMInG 2 3 CONTROL BOARD PCB SL...

Page 2: ...erminals of control unit 4 1 4 DIP switches adjustment 5 1 5 Description of mechanically operated controls 5 2 REMOTE CONTROLLER PROGRAMMING 6 2 1 Cleaning of the receiver s memory 6 2 2 Record of Doo...

Page 3: ...nect warning light see diagram Negative terminal for accessories power supply 24 V 600 mA 24 V Positive terminal for accessories power supply 24 V 600 mA Sw Op Output contact of limit switch to open S...

Page 4: ...To connect some devices it s necessary to connect normally open NO contacts of these devices in parallel Ped command Pedestrian pedestrian crossing NO DIP2 off Ped command results in the door opening...

Page 5: ...to install the jumper between EMRG contact terminals see wiring diagram 7 24 V DC output terminals of power supply transformer with 24 DC max load of 600 mA 1 4 DIP switches adjustment WARNING When ch...

Page 6: ...s in the receiver s memory 60 pcs 2 3 Remote programming for Doorhan remote controllers Perform the items 1 4 within 5 second interval 1 Press and hold down the button 2 see figure of programmed remot...

Page 7: ......

Page 8: ...our company and believe that you will be satisfied with its quality For information on purchasing distribution and servicing contact DoorHan central office at Kralovsky VRCH 2018 Kadan 43201 Czech Rep...

Reviews: