background image

7

* Cables are connected to hydraulic stations and supplied with the dock levelers.

Table 2. Connecting cables to the dock leveler control unit*

#

Part name

Length

Part number

-

Connecting cable for DCUT-1, 2, 3 control units

7 m

DKTL02-2

-

Connecting cable for DCUT-1, 2, 3 control units

10,5 m

DKTL02-3

APPENDIX

Table 1. Control unit spare parts

#

Part name

Part number

1

DCUT-1 main board

PCB_DCUТ1-M/V.1.2

2

DCUT-1 control board

PCB_DCUT1-BT/V.1.0

3

Switch assembly

DCU007

Fig. 1. Control unit design

3

2

1

APPENDIX. RECOMMENDED SPARE PARTS

Summary of Contents for DCUT-1

Page 1: ...s Manual DCUT 1 Control Unit for Electro Hydraulic Dock Leveler with Telescopic Lip General Information 2 Safety Rules 2 Design 3 Installation 3 Electrical Connections 4 Control Unit Operation 5 Troub...

Page 2: ...rol units options Table 1 2 Control unit specifications Parameters Value Supply voltage 380 415 V 50 60 Hz Control voltage 24 VDC Max power of the hydraulic station 1 5 kW Operating temperature 20 50...

Page 3: ...Main power switch 1 Main board 2 Control board Fig 3 1 Closed view Fig 4 1 Control unit installation Fig 3 2 Open view 1 1 2 2 3 4 5 6 Mount the control unit so the distance between control unit bott...

Page 4: ...N PE PE U V W OUT 24 OUT 24 OUT 24 M CONTACTOR PROTECTOIN RELAY TRANSFORMER HYDRAULIC STATION MOTOR ELECTROMAGNETIC VALVE COILS L1 L2 L3 N PE 1 2 3 380 415 V 380 415 V Fig 5 1 Electrical connections...

Page 5: ...rn the main power switch ON and press RAISE button shortly Connection scheme refers to DoorHan operators of Shaft series only Fig 5 2 Connection scheme for lip inductive position sensor 1 Park the tra...

Page 6: ...ring from control unit to coil 1 Check coil 1 voltage 24 VDC Replace main board Faulty electromagnetic valve coil or valve Replace coil or valve see Owner s Manual for Electrohydraulic Dock Leveler wi...

Page 7: ...number Connecting cable for DCUT 1 2 3 control units 7 m DKTL02 2 Connecting cable for DCUT 1 2 3 control units 10 5 m DKTL02 3 APPENDIX Table 1 Control unit spare parts Part name Part number 1 DCUT 1...

Page 8: ...tion on purchasing distribution and servicing contact DoorHan central office at 120 Novaya street Akulovo village Odintsovo district Moscow region 143002 Russia Phone 7 495 933 24 00 E mail info doorh...