Connection Diagram Examples 
 

Common power supply for magnetic lock (Fail open – power to lock) 

 

 

Common power supply for lock release (Fail secure – power to unlock)

 

 

 

Common power supply for auto gate controller (using Normally Open contact)

 

 

 
Comments: 
Relay 2 can be used to operate a doorbell if there is no need to operate a second door. The wiring 
to connect the doorbell is via NO2 and COM2. Press #, the K401-E will send out a switching signal to the 
doorbell, as long as you press the” #”, the doorbell will operate, it will stop when you release the ” #” 

ACCESS 

SECURITY 

PRODUCTS 

LTD

Summary of Contents for KP-401-EX

Page 1: ...KP 401 EX External Stand Alone Keypad Proximity Card Reader User Manual A C C E S S S E C U R I T Y P R O D U C T S L T D...

Page 2: ...K401 E has many extra features including block enrollment anti tamper alarm backlit keypad buttons These features make the K401 E an ideal choice for door access not only for small shops and domestic...

Page 3: ...d Proximity Card 25mm 35mm Wiring Connections Electric Lock Exit Button DOTL External Alarm Door Bell Relay Adjustable Relay Output Time Adjustable Alarm Output Time Lock Output Load Alarm Output Load...

Page 4: ...ed Power Input Black AC DC 12 24V DC 12 18V AC Regulated Power Input Grey Black GND Negative Pole Blue NO1 Normally Open Relay 1 output White COM1 Common Connection for Relay 1 Output Green NC1 Normal...

Page 5: ...ontroller using Normally Open contact Comments Relay 2 can be used to operate a doorbell if there is no need to operate a second door The wiring to connect the doorbell is via NO2 and COM2 Press the K...

Page 6: ...rd to allow rapid card enrollment They are for Relay 1 only Anti Tamper Alarm The K401 E uses an LDR light dependent resistor as an anti tamper alarm If the keypad facia is removed the tamper alarm wi...

Page 7: ...ered Note When adding users if the card fob or Pin user has been enrolled already you can not add it again on the same relay or the device will give a bleep as an error It is ok to enroll the same car...

Page 8: ...o delete Card users by cards Note Users can be deleted continuously without exiting programming mode 3 Read Card The device can automatically identify the card of relay 1 or relay 2 To delete Card use...

Page 9: ...programming mode so the user can undertake this themselves ID number Old PIN New PIN New PIN To delete a Card and PIN user just delete the card 3 Read Card or 3 User ID To set users for relay 2 4 2 1...

Page 10: ...eriod either the keypad will lockout for 10 minutes or the alarm will operate for 10 minutes depending on the option selected below Normal status No keypad lockout or alarm 7 0 Default Keypad Lockout...

Page 11: ...ave been lost 1 Power down the K401 E 2 Press the Star button and hold at the same time power up the keypad 3 Release the button and wait until the amber LED shines Parts 4 5 must be undertaken within...

Page 12: ...ay 1 ON Short Single Bleep Entry Granted for Relay 2 ON Alarm Mode Engaged Flashing Alarm K401 E Simplified Instruction Function Description Operation Enter the Programming Mode Master Code 666666 is...

Reviews: