6-040400 X2 

3

212i Wiring Diagrams

To control the LED’s externally cut the four 
traces in the box underneath connector J1. 
Before connecting the alarm panel’s LED 
control lines to J1 verify the traces are cut. 
To verify, measure continuity between the 
end of the wire on the wire harness and the 
square pad on the circuit board below the box 
corresponding to the wire you’re measuring. 

Permanent damage to the keypad may 
result if voltage is connected to J1 when 
the traces are not cut.