DC-ONE V3
AUTOMATIC DOOR
CONTROLLER
GETTING STARTED
AND
TROUBLESHOOTING GUIDE
Page 1: ...DC ONE V3 AUTOMATIC DOOR CONTROLLER GETTING STARTED AND TROUBLESHOOTING GUIDE...
Page 2: ...ector K J7 Special Modes Connector L J8 Lock Connector M Test Button activates door N Program Button O Menu Down Button P Menu Up Button Q Reset Button R Lock Voltage Selector 12 24 S Display Intensit...
Page 3: ...RN OPEN SPEED Adjust speed to allow door to travel just enough to complete the learn cycle If door isn t traveling fast enough It is recommended to adjust Learn Torque first SELECT MOTOR TYPE It is ve...
Page 4: ...tation CLOSE TORQUE This is where we set the controller power to move the door throughout the entire close cycle If the door will not close properly or moves to slow This is where to start Turn this u...
Page 5: ...SAFE or FAIL SECURE lock BREAKOUT POLARITY Depending on what type of switches your door has either Normally Open or Normally Closed contacts If the breakout panels are closed and the orange LED marked...
Page 6: ...er open and closed when the TEST button is pressed Use caution during this test as the sensors will not be operational The following inputs have status LEDs to help identify problems Power Safety Cont...
Page 7: ...ary Safety beam is blocked or is faulty Correct as necessary Door handing is set incorrectly Enter program mode and change hands Door powers closed and then stay closed Press the TEST button on the fa...
Page 8: ...m satisfactorily Walk test the door according to AAADM recommended guidelines and correct all discrepancies if any before leaving the job site DO NOT compromise proper performance If repairs cannot be...
Page 9: ...ctivate during off one way or night mode o Green LED is on when active Activation o Activates the door during all modes o Green LED is on when active Breakout o Stops door motion o Software selectable...
Page 10: ...N SWITCH WIRING DC ONE V3 Control 5PSW1 5PSW2 5PSW3 5PSW4 J6 x 1 Common x 2 Off x 3 One Way x 4 Partial Open x 5 Hold Open x 6 Reset x 7 24 VAC x 8 24 VAC Return x 9 Common x 10 Safety 1 2 3 4 5 6 x x...
Page 11: ...Controls for further technical support when needed Door Controls USA Inc 321 VZ County Road 4500 Ben Wheeler TX 75754 Phone 1 800 437 3667 Fax 1 800 356 8858 Email parts doorcontrolsusa com www doorco...