7
Indirect
Air Forced Heater
1. Open the fuel tank cap.
2. Remove the fuel with a bellow.
3. Clean the inside of the tank with some kerosene, gasoline or thinner.
Never use water at this time because rust may be fatal.
4. Dry the tank completely.
Never pass the season with the fuel in the tank. Old fuel may give damage
to the product.
Store the product at the dry and well-ventilated area.
Store the product at the place of no dust and moisture in the original
packing box.
Keep the user manual at the place close at hand.
(Measure to the error codes displayed on the
temperature display window)
Long-Time Storage
First-Aid Measure
Display
Window
EO
Power switch handling error
Flame Detector (Photo-electric tube error)
Temperature sensor error
Anti-overheating Sensor Defect
Float Sensor
1.Photo-electric tube defect
3.Incomplete Combustion
3.Contamination of photo-electric tube
4.Contamination of fuel filter
-Ignition trouble
1.Temperature sensor separation
2.Sensor Defect
Unusual internal overheating
In case of below 9 C
Incase of over 50 C
Electronic Circuit Board Defect
1.Re-connection of the sensor
Replacement of temperature sensor
-Re-operating after cooling
Normal
Normal
1.Checking the circuit
2.Re-operating after reset
1.Replacement of Photo-electric tube
2.Replacement to clean fuel
3.Cleaning of photo-electric tube
4.Cleaning of fuel filter
1.Checking the igniter wire
2.Cleaning or replacement
of ignition plug
Shortage of Fuel
Fuel Supply
Power is supplied when
the switch is on.
After plugging it out and turning
the switch off, plug it in and
turn on the switch.
E1
E2
E3
E6
LO
Hi
Blinking
Cause
Measure
Nozzle
Nozzle should be cleaned or replaced at least once a year. If contaminated
fuel is used, the nozzle should be replaced immediately. To clean the
nozzle, take it out from the burner, disassemble it, put it in the thinner or
gasoline for a while and carefully assemble it.
Ignition Plug
Ignition plug should be cleaned or the gap between the electrodes should be
adjusted every 600 hours or at any necessary time. Take it out from the
burner and clean it with steel brush. The gap between the electrodes should
be kept 3.5mm~3.7mm.
Photo-electric tube
Photo-electric tube should be cleaned once a year or at any necessary time.
Clean the photo-electric surface with some cotton cloth dipped in the water
or alcohol.
Photo-electric tube
Air bolwing Motor
Photo-electric tube holder
Air blowing Fan
Burner Head
Lgnition Plug
Support Piece
Igniter
High pressure fuel hose
Nozzle
Ignition Plug
Distributor
Diffuser
Fitting Bolt
Diffusion
Nozzle
Burner head blade
Spark plug
Burner head
Photocell
Blower fan
Blower motor
ZF-80ID
ZF-170ID
ZF-240ID
Do not leave the place with the heater turned on or plugged in.
Summary of Contents for Z Fire Series
Page 1: ...ZF 80ID ZF 170ID ZF 240ID Z Fire...
Page 2: ......
Page 4: ...Do not leave the place with the heater turned on or plugged in...