2.FUNCTIONS
Control Resistance of R sensor OFF Point
- When the refrigeration of refrigerator is poor or weak though Fan and COMP are working continuously,
the following actions are recommended for service.
(1) Resistance (R25) : Default resistance (31.4Kohms)
(2) Resistance (R25+R26) :
Cut the “J2” off to reduce Default R sensor OFF Point by 1.5
°
C. (2Kohms up)
(3) Resistance (R25+R26+27) :
Cut the “J1” off additionally to reduce Default R sensor OFF Point b
y 3.0
°
C.
(total 4Kohms up)
※
R25 = R-SENSOR OFF point
R25 + R26 = R-SENSOR OFF point - 1.5
°
C
R25 + R26 + R27 = R-SENSOR OFF point - 3
°
C
CONTROL OBJECT
INPUT
”J1” , “J2” On Main PCB
2-8. Control of R-sensor OFF Point
16
All manuals and user guides at all-guides.com
all-guides.com
Summary of Contents for FRP-301D Series
Page 8: ...1 6 Wiring Diagram 1 SPECIFICATIONS 8 All manuals and user guides at all guides com ...
Page 9: ...1 7 Main PCB Circuit Diagram 1 SPECIFICATIONS 9 All manuals and user guides at all guides com ...
Page 18: ...3 1 Tank water as 3 DISASSEMBLY 18 2 All manuals and user guides at all guides com ...
Page 19: ...3 2 Door Switch 3 DISASSEMBLY 18 All manuals and user guides at all guides com ...
Page 22: ...3 5 DOOR F R 3 DISASSEMBLY 21 All manuals and user guides at all guides com ...
Page 23: ...3 5 DOOR F R 3 DISASSEMBLY 22 All manuals and user guides at all guides com ...
Page 27: ...5 How To Charge R 600a Refrigerant 26 All manuals and user guides at all guides com ...
Page 28: ...5 How To Charge R 600a Refrigerant 27 All manuals and user guides at all guides com ...
Page 29: ...5 How To Charge R 600a Refrigerant 28 All manuals and user guides at all guides com ...