WSO Mist Collector, WSO M
6
Ceiling-Mounted Units
1. The unit can be suspended or hung from overhead
supports. The supports must be adequate to carry
the live load of the unit and installation performed
to reduce sway or vibration to the unit. The dry
unit weight is shown on the specification control
drawing shipped with the unit.
2. The live load will include the weight of all ancillary
hardware attached to the mist collector, as well as
the weight of the mist-laden, wet filters. Consult the
coolant MSDS for the specific gravity of the coolant
to estimate the weight of the mist-laden, wet filters.
3. Check the Specification Control drawing for weight
and dimensions of the unit, subassemblies, and
components to ensure adequate crane capacity.
Electrical Wiring
Electrical installation, service,
or maintenance work must
be performed by a qualified electrician and
comply with all applicable national and local
codes.
Turn power off and lock out electrical
power sources before performing service or
maintenance work.
Do not install in classified hazardous
atmospheres without an enclosure rated for
the application.
All electrical wiring and connections, including electrical
grounding, should be made in accordance with the local
codes.
Check local ordinances for additional requirements that
apply.
The appropriate wiring schematic and electrical rating
must be used. See unit’s rating plate for required voltage.
An electric disconnect switch having adequate amp
capacity shall be installed in accordance with local
codes codes. Check unit’s rating plate for voltage and
amperage ratings.
Refer to the wiring diagram for the number of wires
required for main power wiring and remote wiring.
The only component requiring electrical power is the
blower motor.