WSO Mist Collector, WSO M
14
Inlet Hopper and Impact Separator
Impact separators are available for remote-mounted
units in operations generating large amounts of small
particulate such as surface grinding, polishing, and high-
speed cutting.
1. Lift the unit approximately 1524 mm (5-ft).
2. Apply sealant around the impact separator toward
the outside of the bolt pattern.
3. Align the impact separator with the bottom flange of
the hopper. Fasten using bolts, washers, and hex nuts
supplied.
4. Apply sealant around the hopper’s top flange toward
the outside of the bolt pattern.
5. Align the top flange of the hopper with the bolt
pattern on the bottom of the unit and secure using
6mm bolts and washers supplied.
Note: Install a 6mm bolt into every rivnut.
6. Fasten the flexible duct to the 152 mm (6-in) side inlet
on the impact separator using a hose clamp.
7. Connect opposite end of flexible duct to a customer-
supplied angular nozzle, inlet collar, or other fitting.
8. Install drain collection container by threading the
container onto the bottom of the impact separator.
The container’s faucet must be closed when the unit
is in operation.
hopper
sealant
impact
separator
sealant
optional drain
collection
container
hose clamp
flexible
duct
hose
clamp
Inlet Hopper with Impact Separator