11
Donaldson Company, Inc.
Collector Stand
If collector drainage is not
properly maintained, the
collector may collapse on stand and cause
severe personal injury or property damage.
Maintain proper collector drainage.
Donaldson Torit equipment is not designed to
support site installed ducts, interconnecting
piping, or electrical services. All ducts, piping,
or electrical services supplied by others must
be adequately supported to prevent severe
personal injury and/or property damage.
For applications with limited mounting surfaces, an
adjustable stand is available. Bolt the stand’s base
securely to the floor, attach the collector, and adjust
height from 1676 to 2590 mm (66 to 102-in).
1. Install customer-supplied 3/8-16 anchor bolts in the
floor extending 38 mm (1 1/2-in) above surface.
2. Level the collector stand and tighten anchor bolts
securely.
3. Lift the unit and remove the bolts from the access
panel located on the bottom of the unit. Remove bolts
only. Do not remove access panel.
4. Adjust the stand height by loosening the four locking
bolts on the upper portion of the stand. Slide this
section up to obtain the required height. Tighten
bolts securely. Do not adjust the stand over 2590 mm
(102-inches).
5. Using a crane or forklift, lift the unit into position over
the stand and lower slowly.
6. Fasten the top plate of the stand to the unit using the
bolts removed in Step 3.
7. Tighten all hardware and remove crane.
stand
extension
locking bolt
flat washer
lock washer
flat washer
hex nut
base
2590 mm (102-in)
maximum
Collector Stand