Torit PowerCore, CPV-1 to CPV-12
12
Filter Removal and Installation
Use proper safety and protective
equipment when removing
contaminants and filters.
Dirty filters may be heavier than they appear.
Use care when removing filters to avoid
personal injury.
Filter Removal (CPV-1 Only)
When inserting the filter pack,
start at the back edge of the pack
first to ensure alignment tabs do not damage
the filter packs.
1. Turn power to unit OFF.
2. Loosen wing nuts and slide filter retainer left to
release from hold down.
3. Lift left side of retainer up while moving the right side
towards the back wall.
4. Pull the raised left side of the retainer through upper
left of opening.
5. Remove pack vertically until clear of tubesheet.
Filter Installation (CPV-1 Only)
1. Insert the filter pack, starting with the back edge
first, to ensure alignment tabs do not damage filter
pack.
2. Slide the right side of the retainer through lower right
of opening.
3. Lower the right side of retainer while moving the left
side toward the back wall.
3
2
1
Filter Retainer Removal (hinged access panel removed for clarity)
Filter Removal and Installation
(hinged access panel removed for clarity)
Filter Removal and Installation for CPV-1 Units