5
Donaldson Company, Inc.
During normal operation, contaminated air enters the collector through the dirty-air inlet on the bottom of the unit. The air passes
through a reusable first-stage filter designed to collect and coalesce large droplets and particles. Smaller mist droplets pass to a
second-stage filter wrap where the small droplets coalesce into larger droplets.
The third and most efficient stage of filtration is the pleated filter specifically designed to collect, coalesce, and drain fine mist. As
the mist coalesce, the droplets are big enough to run down the element and drain back into the collector. The droplets will drain
on both the inside and outside of the filter cartridge. Liquid that collects on the inside of the cartridge drains back into the machine
center. Clean, mist-free air exits the filter cartridge and discharges near the top of the collector.
Collector Operation
Electrical work during installation, service or maintenance must be performed by a qualified electrician and comply
with all applicable national and local codes.
Turn power off and lock out all power before performing service or maintenance work.
Turn compressed air supply off, bleed and lock out lines before performing service or maintenance work.
Check that the collector is clear and free of all debris before starting.
Do not install in classified hazardous atmospheres without an enclosure rated for the application.
clean-air outlet
clean-air plenum
exhaust pack
third-stage filter
second-stage
filter wrap
large droplets
dirty-air inlet
and collected mist drain
large droplets
first-stage filter
fan motor
fan
3 Operation