24 FAILURES
This section provides an index of the most common failures in both the burner and boiler.
Burner failures:
It has already explained that the burner is equipped with a locking system indicated by a light,
and it could unintentionally occur that it becomes locked making the push button be put on. In
this case, unlock it by pressing the push button.
FAILURE CAUSE
REMEDY
- Oil valve closed
Open
- Power supply is not reaching the boiler
Check
- Nozzle faulty or dirty
Replace or clean
- Poorly-adjusted electrodes
Adjust
- Timer at automatic position
Set it to manual
IT DOES NOT
PUT ON
- Poorly-set room or boiler thermostat
Set properly
- Nozzle faulty
Replace
- Flame sensor dirty
Clean
- Fume circuit clogged
Clean
FREQUENT
LOCKING
- Oil filter or burner pump dirty
Clean
Boiler failures:
FAILURE CAUSE
REMEDY
- The pump does not rotate
Unlock the pump
RADIATOR
DOES NOT
HEAT
- Air in hydraulic circuit
Drain the installation and
boiler (The air vent plug
is always to be loose)
- Poorly-adjusted burner
Adjust properly
- There is no sealing on the uptake
Eliminate the leakage
- Unstable flame
Check the burner
EXCESSIVE
NOISE
- Uptake with no thermal insulation
Insulate properly
Summary of Contents for EVOLUTION EV FDX
Page 1: ...INSTALLATION AND OPERATING INSTRUCTIONS EVOLUTION EV FDX ER 0170 1996 CGM 04 392 ...
Page 2: ......
Page 5: ...Evolution FDX 2 22 16 OIL EASY CONNECTION 28 23 ALARM CODES 30 24 FAILURES 31 ...
Page 6: ......
Page 11: ...Evolution FDX 6 ...
Page 26: ...21 TR DHW recirculating connection 1 2 H ...
Page 30: ......
Page 41: ...Evolution FDX 32 NOTES ...
Page 42: ...33 NOTES ...
Page 43: ...Evolution FDX 34 NOTES ...
Page 44: ...35 ...