Installation Instructions

MAYFAIR

Wall/Ceiling Fan

NOTICE

PLEASE READ

INSTALLATION IN-

STRUCTION

BEFORE INSTALLING

ISSUE 3

LAB305R

TO PROFESSIONAL INSTALLERS:

Please leave this instruction booklet with the fan

on completion of the installation.

WARNING

Isolate power supply before removing front cover or cleaning fan unit.

TIMER ADJUSTMENT
All models with timers

To adjust the timer, the front cover must be removed. To do this, remove the retaining screw on the bottom 
edge and lift off cover. It is not necessary to remove the fan from its mounting. The timer adjuster is clearly 
marked. With a small screwdriver turn anti-clockwise for less overrun time. The timer range is approximately 
30 seconds to 25 minutes.

CONDENSATION CONTROL ADJUSTMENT
All models with condensation controls

To adjust the condensation control, the front cover must be removed. To do this remove the retaining screw 
on the bottom edge and lift the cover off. It is not necessary to remove the fan from its mounting. The conden-
sation control adjuster is clearly marked. With a small screwdriver turn anti-clockwise for less sensitivity and 
clockwise to increase sensitivity. The condensation control range is from 50% RH to 90% RH. The control is 
set approximately half way at the factory. The condensation control may be tested by breathing through the 
sensor grille on the front cover.

Note.

 There is a short delay between breathing through the grille and the fan starting. Do not use steam from 

a kettle to test the unit.

CLEANING/MAINTENANCE

From time to time the fan unit will need cleaning. To do this, first isolate power supply. Remove front cover as 
described above. Remove the fan from its mounting by undoing the four corner screws. Dust the fan from its 
mounting by undoing the four corner screws. Dust the fan unit with a dry brush. Do not immerse in water. The 
front cover can be washed in warm soapy water. The filter fitted in filtered fans can be washed by hand in warm 
soapy water. Hang filter up to dry. Do not wring. The inlet/retaining grille can be washed as the front cover.

GUARANTEE

This product is guaranteed against faulty manufacture for a period of two years.

WARNING: Failure to comply with installation instructions and

cautionary notes may invalidate warranty.

Further Information

This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental 
capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction 
concerning use of the appliance by a person responsible for their safety.

V E N T I L A T I O N

Domus Ventilation

Cambria House
Caerphilly Business Park
Van Road
Caerphilly
CF83 3ED
Tel: +44 (0)3443 715523
Fax: +44 (0)3443 715524
Email: [email protected]
www.domusventilation.co.uk

V E N T I L A T I O N

Summary of Contents for MTD 070B

Page 1: ...by breathing through the sensor grille on the front cover Note There is a short delay between breathing through the grille and the fan starting Do not use steam from a kettle to test the unit CLEANING MAINTENANCE From time to time the fan unit will need cleaning To do this first isolate power supply Remove front cover as described above Remove the fan from its mounting by undoing the four corner s...

Page 2: ...and will give many years of reliable service APPLICATION BATHROOMS TOILETS UTILITY ROOMS LOBBIES AND HALLWAYS The Mayfair 2000 complies with all current Building Regulations Description Model 70 70m3 h 20 l s 43m3 h Extract Volume High Speed Extract Volume Low Speed Options Single Speed Single Speed Pull Cord Single Speed Time Delay Twin Speed Twin Speed Time Delay Single Speed Condensation Contro...

Page 3: ...ated and do not require earthing The mounting system is provided with an earth termination for convenience only Wiring Installation S L N S L N OPERATING SWITCH ISOLATOR SWITCH FRAME TERMINALS S L SWITCH LIVE N NEUTRAL L N L N ISOLATOR SWITCH FRAME TERMINALS L LIVE N NEUTRAL Models MSS 070B Models MPC 070B MIR 070B A guide to Ventilation WHERE TO SITE YOUR FAN Incorrect siting of an extractor fan ...

Page 4: ...l as possible cut a hole through the wall to take a 100mm duct for the fan discharge This should slope downwards towards the outside to allow for condensation drainage When this is done position the building in frame with the discharge outlet at the top right over the duct hole Mark around the frame and cut an aperture to take the frame and fan It is important that the front edge of the frame is f...

Reviews: