55
3.5 Injector replacement.
If the appliance is installed in a country where it is necessary to change the injector diameter or
even to install the appliance ready for operation with another type of approved gas, please call the
technical service
to make the change.
Please follow the instructions below to change the gas supply from propane to natural gas.
PROCEDURE:
All the dryers are fitted with a 1/2” gas inlet. Never connect a pipe with an inner diameter less than
this.
1-
Locate the Injector “D” on the left side of the valve covered by a metal plate. Unscrew and
remove the injector using the socket wrench nº 13.
2- Replace the injector with the one contained in the hanging bag.
3- Connect the gas inlet
“E” ½”.
4-
Loosen the bolt in opening “B” of the valve one turn in an anti-clockwise direction.
5- Connect the manometer on nozzle
“B”.
6-
Remove the solenoid valve plug “C”.
7- Adjust the gas inlet screw (C) until the required pressure is reached according to the table on
page 17. Do not over tighten the nylon screw as this could break the internal spring and
result in fuel leaks.
8- Replace
the solenoid valve plug “C”.
9- Remove the manometer pipe.
10- Tighten bolt
“B”.
-When the machine has been modified to work with a different type of gas to that
specified, put the corresponding new name plate and yellow label on it, which is
inside the plastic bag of the new injectors.
TOOLS REQUIRED
No 13 socket wrench
Manometer
Flat-head screwdriver
Natural gas injector (found in the BAG close
to the valve).