GENERAL SETTINGS
NOW
HOT WATER MAINTENANCE
BOILER
ECONOMY TEMP
AT 17:
00
NEXT
INFO, RESET, SERVICE, TEST....
CABLE TYPE, PIPE DAIMETER,...
COUNTRY, LANGUAGES, UNITS,...
APPARTMENT, MAINTAIN, ECONOMY,....
SETTING
SYSTEM
HEATING CABLE & PIPE
GENERAL SETTINGS
WATER TEMP. & PROGRAM
INFO
TEST PROGRAM
RESET
SERVICE
STATUS
SYSTEM
SELECT LANGUAGE
SELECT COUNTRY
SELECT DATE
SELECT TIME
SELECT ALARM
GENERAL SETTING
S
SELECT SAVING TIME
ENGLISH
GERMANY
01.10.2017
14 : 17
OFF
ON
14 : 17
14 : 17
14 : 17
14 : 17
14 : 14
SELECT WATER TEMPRATURE
SELECT PROGRAM
PROGRAM TIMER
WATER TEMP. & PROGRAM
55 °C / 50°C
14 : 17
HOTEL
SELECT CABLE TYPE
SELECT PIPE DIAMETER
SELECT INSULATION THICKNESS
SELECT AMBIENT TEMPERATURE
SELECT BOILER SENSOR
SELECT BOILER CUT-OFF TEMPS.
HWAT-M
DN 25
40 MM
20 °C
ON
35/85 °C
HEATING CABLE & PIPE
Language
C
hoose your language from the language menu.
C
ountry
S
elect a country in this menu.
Y
our selection defines
the default
values used for time format, pipe diameter and insulation
thickness.
Date
U
se the
+
/
-
keys to select the year.
A
fter a power break of more
than 15 days you need to re-enter the date.
Time
U
se
+/- keys
to set hour and minute.
A
fter a power break of
more than 15 days you need to re-enter the time.
Alarm tone An alarm will go off inside the unit indicating an error
condition.
A
ctivate/deactivate the alarm by pressing
ON
/
O
FF.
N
ote: alarm messages and an alarm signal will be created any
time in case of a malfunction.
Water temp. & Programming
NOW
HOT WATER MAINTENANCE
BOILER
ECONOMY TEMP
AT 17:
00
NEXT
INFO, RESET, SERVICE, TEST....
CABLE TYPE, PIPE DAIMETER,...
COUNTRY, LANGUAGES, UNITS,...
APPARTMENT, MAINTAIN, ECONOMY,....
SETTING
SYSTEM
HEATING CABLE & PIPE
GENERAL SETTINGS
WATER TEMP. & PROGRAM
INFO
TEST PROGRAM
RESET
SERVICE
STATUS
SYSTEM
SELECT LANGUAGE
SELECT COUNTRY
SELECT DATE
SELECT TIME
SELECT ALARM
GENERAL SETTING
SELECT SAVING TIME
ENGLISH
GERMANY
01.10.2017
14 : 17
OFF
ON
14 : 17
14 : 17
14 : 17
14 : 17
14 : 14
SELECT WATER TEMPRATURE
SELECT PROGRAM
PROGRAM TIMER
WATER TEMP. & PROGRAM
55 °C / 50°C
14 : 17
HOTEL
SELECT CABLE TYPE
SELECT PIPE DIAMETER
SELECT INSULATION THICKNESS
SELECT AMBIENT TEMPERATURE
SELECT BOILER SENSOR
SELECT BOILER CUT-OFF TEMPS.
HWAT-M
DN 25
40 MM
20 °C
ON
35/85 °C
HEATING CABLE & PIPE
Maintain/
Economy
temp.
The maintain temperature is the water temperature that you set
for normal use.
T
he minimum temp
.
is 37°
C
or the economy temperature,
whichever is higher.
T
he maximum temperature depends on cable type, pipe
thickness, insulation thickness and ambient temperature.
T
he economy temperature is the water temperature for periods
in which the amount of hot water used is low (at night) or high
(peak period). Select the temperature using the +/- keys.
The maximum temp
.
is the selected maintain temperature.
Building
type
program
the Therm-Control has 7 default timer programmes.
S
elect by
tapping on the programme of choice (box will turn
blue
).
S
ee
figure
s
for the schedule of each programme.
T
he building programme reflects the tapping profiles.
G
raphically programme the timer in 1 hour time blocks.
You can set a block to OFF, Economy temp or Maintain temp.
OFF
MAINTAIN
ECONOMY
50
| Domotec.ch
Timer
schedule
Summary of Contents for Therm-Control DHB 370 C
Page 4: ...2 INSTALLATION INSTALLAZIONE 1A 1B Therm Control 2 150mm 3 5 4 Domotec ch ...
Page 5: ...4 5 1 2 A B C 6 Domotec ch 5 ...
Page 6: ...7 8 9 L L L N AC 230 V 25 6 Domotec ch DE 25 FR 25 IT 25 EN ...
Page 7: ...10 11 12 CLICK Domotec ch 7 ...
Page 8: ...13 14 15 RCD 20 A ON 8 Domotec ch ...
Page 56: ......