6.0 TROUBLESHOOTING
Reference to Known Misuse
Filters
•
Opening inlet valve too quickly, causing initial high differential pressure across
filter element.
Inlet / outlet head
•
Pipe diameter too small
•
Pipework unsupported
•
Inlet pipework taken from low point of manifold range allowing bulk water
intrusion into the dryer.
Electric control box
•
Incorrect wiring configuration by user or incorrect supply voltage.
•
No fuse fitted or fuse blown.
Additional items
•
Use of non-recommended components.
•
Untrained, unauthorised maintenance / installation personnel used.
•
Subsequent increase in air consumption without relation to dryer flow capacity.
•
Purging of pneumatic system and dryer with cleaning agents that have the
potential to damage desiccant material.
•
Covers removed or loose during operation.
•
Cartridges and filter / autodrain not changed when red LED is illuminated.
LED failure.
Problem
Indication
Probable Cause
Remedy
Poor Dewpoint
N/A
Entrained Water
Check pre-filtration and pre-filtration drains
Excessive air flow demand
Check actual flow against rated flow of dryer
Check for recent additions to air system
Inlet pressure too low
Check against technical specification
Excessive inlet air
Check against technical specification
temperature
Insufficient purge air flow
Factory set for 6 barg (87 psi g) system pressure
Exhaust silencers blocked
Change by domnick hunter trained personnel
Contaminated desiccant
Eliminate source of contamination. Desiccant
change by domnick hunter trained personnel
Cartridges not fitted
Check and fit cartridges
Electrical Fault
Power LED ‘OFF’
Hardware fault
Contact domnick hunter customer service
Failure to purge
No depressurisation
Purge valve blocked or shut
domnick hunter trained personnel to adjust
and poor dewpoint
Exhaust silencer blocked
Change by domnick hunter trained personnel
Outlet air flow
Downstream
No air supply to the
Check compressor air supply to dryer
stops
pressure drops
dryer
Check all pipework and fittings for leaks
Constant
Erratic air flow from
Damaged valve
Change by domnick hunter trained personnel
depressurisation
exhaust
Summary of Contents for Pneudri Midas DAS 1
Page 123: ...121 domnick hunter domnick hunter domnick hunter domnick hunter...
Page 124: ...122 E 1 0 1 2 0 2 3 0 6 4 0 8 5 0 9 6 0 10...
Page 128: ...126 2 3 O E O O T500mA CSA NPT 230V 50 60Hz 115V 50 60 Hz Brown Blue Live Earth Neutral T500mA...
Page 129: ...127 Y OMNHMA A E B B F B C G B D A H O 2 4 1 3 8 BSP NPT H K...
Page 131: ...129 2 5 E DASRDK 1 2 DASMB1 DASMB2...
Page 133: ...131 3 4 M LED LED 3 5 D K F K E D K F G E H G...
Page 134: ...132 4 0 LED LED E 500 6 24 domnick hunter domnick hunter T T A...
Page 183: ......