Domitech ZSC User Manual Download Page 8

You

 

can

 

set

 

the

 

smart

 

bulbs

 

into

 

Group

 

2

 

or

 

Group

 

3.

 

Maximum

 

of

 

5

 

Smart

 

Bulbs

 

can

 

be

 

added

 

in

 

each

 

group.

 

 
 

5.

 

CONTROL

 

MODE

 

You

 

can

 

set

 

the

 

ZSC

 

to

 

control

 

other

 

devices

 

or

 

they

 

issue

 

various

 

scene

 

activation

 

commands

 

to

 

a

 

central

 

controller.

 

Parameter

 

No:

 

2

 

Length:

 

1

 

Byte

 

Valid

 

Values

 

=

 

0,

 

1,

 

2

 

(Default

 

0)

 

Value

 

=

 

0:

 

ZSC

 

can

 

activate

 

the

 

Scene

 

which

 

is

 

pre

set

 

by

 

Gateway,

 

and

 

then

 

control

 

the

 

associated

 

Smart

 

Bulbs

 

in

 

either

 

Group

 

2

 

or

 

Group

 

3.

 

Value

 

=

 

1:

 

ZSC

 

can

 

only

 

activate

 

the

 

Scene

 

which

 

is

 

pre

set

 

by

 

Gateway.

 

Value

 

=

 

2:

 

ZSC

 

can

 

only

 

control

 

Smart

 

Bulbs

 

in

 

Association

 

Group

 

2

 

and

 

Group

 

3.

 

 
 

6.

 

REVERSE

 

BUTTON

 

If

 

the

 

ZSC

 

is

 

installed

 

upside

 

down,

 

you

 

can

 

set

 

the

 

below

   

Parameter

 

No:

 

4

 

Length:

 

1

 

Byte

 

Valid

 

Value

 

=

 

0

 

or

 

1

 

(Default

 

0)

 

 
 

7.

 

EXCLUSION

 

Step

 

1,

 

place

 

your

 

network

 

controller

 

into

 

Exclude

 

mode

 

by

 

following

 

the

 

controller

 

manufacturer’s

 

instructions.

 

 

Step

 

2,

 

press

 

any

 

button

 

on

 

the

 

ZSC.

   

 

Step

 

3,

 

the

 

LED

 

will

 

flash

 

twice

 

and

 

ZSC

 

exclusion

 

is

 

successful.

 

 
 

8.

 

FACTORY

 

RESET

 

Press

 

the

 

Top

 

button

 

3

 

times

 

and

 

then

 

Bottom

 

button

 

3

 

times

 

very

 

quickly

 

within

 

2

 

seconds.

 

LED

 

will

 

flash

 

7

 

times

 

if

 

RESET

 

is

 

successful.

   

Repeat

 

procedure

 

until

 

the

 

LED

 

flashes

 

7

 

times.

 

 
 

IMPORTANT

 

NOTE:

   

Please

 

note

 

that

 

it

 

is

 

extremely

 

important

 

to

 

follow

 

the

 

above

 

procedure

 

to

 

have

 

ZSC

 

operate

 

properly

 

with

 

your

 

home

 

gateway.

   

Installation

 

of

 

ZSC

 

ensures

 

that

 

the

 

power

 

to

 

the

 

smart

 

light

 

bulb

 

always

 

remains

 

ON.

   

Without

 

the

 

electrical

 

power

 

to

 

the

 

Smart

 

Bulb,

 

the

 

Smart

 

Bulb

 

cannot

 

be

 

turned

 

ON

 

remotely

 

nor

 

function

 

as

 

a

 

signal

 

repeater

 

to

 

maintain

 

proper

 

Z

Wave

 

network.

   

 

About

 

the

 

Z

Wave

 

500

 

Series

 

Module

 

with

 

Z

Wave

 

Plus

 

features:

 

You

 

can

 

use

 

a

 

Z

Wave

 

certified

 

portable

 

or

 

static

 

controller

 

to

 

communicate

 

with

 

your

 

Z

Wave

 

devices.

 

Depending

 

on

 

the

 

capability

 

of

 

your

 

controller

 

or

 

gateway

 

software,

 

the

 

following

 

simple

 

to

 

advanced

 

operations

 

may

 

be

 

performed.

 

Please

 

refer

 

to

 

the

 

controller

 

or

 

gateway

 

manual

 

for

 

details.

 

1.

 

Add(Include)

 

or

 

Delete(Exclude)

 

the

 

Smart

 

Bulb

 

to/from

 

your

 

network

 

2.

 

Turn

 

On

 

or

 

Off

 

the

 

Smart

 

Bulb

 

remotely

 

3.

 

Dim

 

up/down

 

individual

 

Association

 

Group

 

or

 

turn

 

on

 

the

 

Scene

 

which

 

is

 

pre

set

 

by

 

Summary of Contents for ZSC

Page 1: ...Model ZSC Wireless Control Device Z wave Switch Cover ZSC This product speaks with other Z Wave certified devices...

Page 2: ...brands of Z Wave LED Light control devices Over The Air firmware upgrade available with compatible gateway Z Wave static controller PC and software Powered by Z Wave 500 Series module inside Manual re...

Page 3: ...attery compartment should be on the bottom side and existing wall switch should be in ON position Make sure the surface is clean and dry before securing Step 3 secure the ZSC tightly by pressing firml...

Page 4: ...ws on the existing wall plate Step 2 remove the existing wall plate from the In wall Switch Step 3 place the bottom case of ZSC to the In wall switch Make sure the existing switch is in ON position St...

Page 5: ...xisting wall plate that you wish to cover do NOT remove the screws on other switch nor the wall plate Step 2 place the bottom case of ZSC main unit on top of the existing faceplate Make sure the exist...

Page 6: ...e room as your home gateway in case the preferred switch location is out of range initially Repeat step 1 3 until the ZSC is added to your network Once the ZSC has been successfully added to your home...

Page 7: ...Controller software Association may be referred to as Smart Apps If Then type conditions etc Step 3 switch OFF and then ON the Smart Bulb for setting the Smart Bulb as a DESTINATION Step 4 press any b...

Page 8: ...8 FACTORY RESET Press the Top button 3 times and then Bottom button 3 times very quickly within 2 seconds LED will flash 7 times if RESET is successful Repeat procedure until the LED flashes 7 times...

Page 9: ...against harmful interference in a residential installation This equipment uses generates and can radiate radio frequency energy and if not installed and used in accordance with the instruction may ca...

Page 10: ...tion and maintenance of the product in accordance with installation instructions and the operating manual supplied to customer Warranty claims must be made by customer in writing within 30 days of the...

Reviews: