SET
TARGET
CURRENT
Press
OK
for 3 seconds,enter into P1~P8 program setting
Press
SET
,switch between P1~P8, for example we choose P2
Press
OK
,TARGET is flashing
Press
UP/DOWN
,set the TARGET value
Press
OK
Press
UP/DOWN
,choose(
MO,TU,WE,TH,FR,SA,SU,MO-FR,
MO-SA, SA-SU, MO-SU
)
Press
OK
Press
UP/DOWN
,set hour of
P2 ON
Press
OK
Press
UP/DOWN
,set minute of
P2 ON
Press
OK
Press
UP/DOWN
,set hour of
P2 OFF
Press
OK
Press
UP/DOWN
,set minute of
P2 ON
Press
OK,
back to program switching interface, at this time, you
can press
SET
button switch to P1, P3,P4,P5,P6,P7,P8,
repeat above steps to set other programs.
1. When
CURRENT< TARGET
, it will be in ON status,the flame symbol
( )will display in LCD,turn on connected heaters,start to warm the
room, so the room temperature is rising.
2. As current temp. rising,
CURRENT=TARGET
, it will be in OFF status,
the flame symbol( )will disappear,remote thermostat will send OFF
commands to turn off all connected heaters.
3. The current temperature will be decreasing, when current temp.
decreased
1°C/1.8°F
, it will turn on all connected heaters once again,
then infinite loop.
8. Working principle
So in the
HEATING
mode, remote thermostat control will automatically
keep the room temp. in below range:
Target Temp.-1
°C
/1.8°F
≥
Room Temp.
≥
Target Temp.
Heating Mode:
9. Other functions
Children Lock
In any mode(except standby mode),
child lock will be activated if no activity
for 10 minutes, the child lock symbol( )
will appear in the top of LCD display.
Press
DOWN
button for 3 seconds to
disengaged child lock.
1. When
CURRENT> TARGET
, it will be in ON status,the snow symbol
( )will display in LCD display,turn on connected cooling devices,
start to cool down the room, so the room temperature is decreasing.
2. As current temp. rising,
CURRENT=TARGET
, it will be in OFF status,
snow symbol( )will disappear from LCD display,remote thermostat
will send OFF commands to turn off all connected cooling devices
3. The current temperature will be rising, when current temp. increased
1°C/1.8°F
, it will turn on all connected cooling devices once again,
then infinite loop.
So in the
COOLING
mode, remote thermostat control will automatically
keep the room temp. in below range:
Target Temp.
≤
Room Temp.
≤
Target Temp.+1
°C
/1.8°F
Cooling Mode:
5. Program setting
Pic.2
Pic.3
For example,
we set as
30°C,MO-FR,18:00~23:00,
show in Pic.2 and Pic.3
It means, from Monday to Friday, 18:00 to 23:00,
TARGET
temperature
change to 32°C,in other time, keep in 25°C
(
Standard heating mode,see Pic.1
)
SET
TARGET
CURRENT
6. Turn on/Turn off P1~P8 programs
7. How to switch Heating/Cooling mode
TARGET
CURRENT
CLOCK
Pic.4
Reset
During heating/cooling mode,
Press
UP&DOWN
button at the
same time for 3 seconds.
The green backlight will flash 3 times,
all setting will be deleted, and back to
factory setting.
SET
OK
CLOCK
CURRENT
TARGET
HEAT
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Remark:
*
P1~P4
, it is period for
HEATING,
P5~P8
, it is period for
COOLING
* During setting, if you don’t want to set, press
POWER
button to exit.
* During setting, if no operation for 10 seconds,automatically save and exit.
1 3 5 7 9 1113 15
2
4 6 8 10 1214
SET
OK
TARGET
CURRENT
CLOCK
3
1
2
Press
SET
, enter programming ON/OFF selection,
ON or OFF(default) symbol is flashing.
Press
UP/DOWN
to select the ON,or OFF.
ON:
turn on all programming at once,
P
display next to
the time,the P1~P8 program is working(see Pic.4).
OFF:
turn off all programming at once,
P
disappear,
only standard heating or cooling is working.
Press
OK
1
2
3
SET
OK
CLOCK
CURRENT
TARGET
HEAT
3
2
Press
UP
for 3 seconds,enter selection between
heating (default) and cooling mode
Press
UP/DOWN
,select Flame( ) or Snow symbol( )
Flame represents HEATING mode
Snow represents COOLING mode
Press
OK
1
1
2
3
1
SET
OK
CLOCK
CURRENT
TARGET
HEAT
2 6
1
1
2
SET
OK
CLOCK
TARGET
CURRENT