Blindmax – User manual
Foreword
•
The Blindmax module is able to supply power to bidirectional
command devices such as electrovans, motors, motorized
shutters,… controlled with 3 wires.
•
In order to configure the Blindmax, it is required to have one or
two external pushbuttons connected. It can be mounted behind
an already existing switch.
•
The module must have its own power supply (Phase, Neutral).
•
It can be used with the pushbutton and/or the Dmax app.
•
It can usually be used with the following modes: follower or trip
switch.
Wiring and configuration of the Blindmax
These steps must be carefully
followed:
1.
Plug the Blindmax according to the
hereby enclosed diagram (cut off
the 230V with the circuit breaker
first). The wiring is done via the
terminals.
2.
The different modes of the
Blindmax can be selected with the
Dmax application available for free
on Google Play or the Apple App
Store. After reconnecting the 230V,
do a scan and
follow carefully the full
authentication procedure to add the
corresponding Blindmax. Go to
settings to edit the operating modes.
For further details about the app,
see the user instructions available
at w
3.
Connect the output and validate it
commutes correctly (the ex-factory setting of the Blindmax
allows commuting the output via a short push and maintaining
the state via a long push).
•
The Blindmax does not commute correctly (irregularly or
not at all)?
Carefully read the tutorial available on the website.
4.
Now adjust the Blindmax performance from the Dmax by
Domintell app.
In case you have a question, see the detailed version at
Technical data
Item number
Type
Contact maximum intensity
Dimensions
5425014390308
Blindmax
BLE
2 x 5 A max. 250 Vac
or 30 Vdc max.
46 x 45 x 18
(mm)
EN_20190709
•
Nominal conditions: 230V AC +/- 15%, 50 Hz, Ambient
temperature: -10°C to 40°C.
•
Maximum wiring section per contact = 2,5 mm².
•
1 self-resettable protection: against overcurrent and
temporary overheating.
•
IP20 protection level.
Safety and environment
•
Without halogen, RoHS.
•
Storage conditions: Temperature: -25°C / +70°C, Relative
humidity: < 75%.
•
For a safe installation, the device can only be mounted
by a qualified electrician.
•
The device must not be opened in any case (cancels
warranty).
•
The device can only be installed inside, in a dry place,
compatible with IP20 devices.
•
During the mounting and unmounting of the device, cut
off the 230V circuit-breaker.
•
After installation, the connector must be protected so that
could not be accessible for the final user.
Pushbutton control
For a LONG PUSH (> 0,4s) on one of the two buttons: the
motor turns on and the Blindmax maintains its output ON as
long as the button is hold. The motor turns off when the
button is released.
For a SHORT PUSH (<0,4s) on the button: The Blindmax
commutes its output state, if it was OFF, it turns ON and vice-
versa. The motor remains ON for a time defined by the user
through the app.
The user can also choose using only a single button which
he configures through the app. With a short push, the motor
goes one way. On the next push, the motor goes the other
way. For a long push, the motor goes one way as long as the
button is pressed. On the next long push, the motor goes the
other way.
Directives and norms
The Blindmax complies with the following directives and
standards:
Directives
RED-directive : 2014/53/UE
EMC-directive : 2014/30/UE
LV-directive : 2014/35/UE
Norm
EN 60669-2-1 : 2004 + A1: 2009 +A12: 2010
Blindmax
is manufactured in Belgium by:
Domintell S.A.