STIIC Controller
6 Installation and Setup
This STIIC PLC is set up with basic factory defaults, so the
control requires configuration to match the constraints of
the devices that are installed in the vessel.
6 .1 Making Terminal Connections in
the Electric Box
WARNING: ELECTRICAL SHOCK HAZARD .
Exercise extreme care when working around
energized equipment. Failure to obey this warning
could result in death or serious injury.
The STIIC PLC electric box comes in two different versions,
one with a 24 VDC power supply and one without the
24 VDC power supply. The components inside the electric
box are powered using 24 VDC. Verify which model is
being installed. Figure 6 shows the STIIC PLC electric box
without the 24 VDC power supply.
6
STIIC PLC Electric Box
Make the following connections to the electric box:
1. Wire the input power to the circuit breaker labeled
“CONTROL”.
2. Wire the three-wire communication cable from the
devices installed in the vessel to the appropriate
terminal in the STIIC PLC electric box:
– Wire MODBUS controlled units only to MODBUS
feedthroughs.
– Wire CANBUS controlled units only to CANBUS
feedthroughs.
Refer to Figure 5 on page 9 and the “Connection
Port Table” on page 10 for information on the correct
port to use when connecting Dometic devices to the
STIIC PLC.
Connection Port Table
Dometic Devices
Connection to STIIC PLC
Platinum Chiller
MODBUS Communication
VARC Chiller
MODBUS Communication
Fresh Air Makeup PLC
Control
MODBUS Communication
XTC SeaXchange
MODBUS Communication
ZTC SpotZero
MODBUS Communication
XZ Combination
MODBUS Communication
Shipwide Ventilation
MODBUS Communication
Eskimo Ice
CANBUS Communication
Room Controls
CANBUS Communication
KRA
MODBUS Communication
6 .2 Connecting the Touchscreen
WARNING: ELECTRICAL SHOCK HAZARD .
Verify that all unit power lines are in unison phasing
to eliminate the potential for a short circuit. Failure
to obey this warning could result in death or serious
injury.
Figure 7 shows the available Touchscreen connection
ports.
7
Touchscreen Connections
q
Power Input (24 VAC)
e
Ethernet Connectivity
Port
w
USB Port
r
MODBUS
Communication Port
(serial port 1)
Make the following connections to the touchscreen:
1. Connect a 24 VAC power supply to the power input.
2. Connect a three-core communication cable to serial
port 1.