24
Automatic mode (RMV5305 only)
I
In automatic mode, the refrigerator selects the most favourable operating mode
available itself.
➤
Press the
button.
7.3
Selecting the temperature
I
➤
Set the required temperature with the
button. You can see the set
temperature in the display
:
–
one bar = lowest cooling capacity
–
five bars = highest cooling capacity
NOTE
•
To avoid unintentionally switching to gas operation while refuelling,
the automatic mode starts the gas operation only once the engine
has been off for 15 minutes.
•
Turn off the refrigerator or set it to a different operation mode, if
refuelling lasts longer than 15 minutes.
Priority
Operating mode
1
Solar (DC power)
2
AC power
3
DC power
4
Gas
NOTE
•
For ambient temperatures of +15 °C up to +25 °C, select the centre
position (fig.
3
, page 4). The unit operates in the optimum power
range.
•
In DC power mode, the refrigerator works without thermostatic
control (permanent operation).