Installing the refrigerator
RML9xxx
20
6.3
Making air inlet and outlet vents
I
➤
Make an air inlet vent and an air outlet vent in the outer wall with the size of
410 mm x 249 mm. When doing so, observe the information, see chapter “Pre-
paring the installation” on page 17.
If the ventilation grille of the air inlet vent cannot be installed flush with the floor of the
niche, you need to install an inlet vent in the floor:
➤
Make an air inlet vent in the floor (fig.
3
4, page 4) behind the refrigerator near
the gas burner.
➤
Shield the end of the opening with a deflector to prevent sludge or dirt from get-
ting inside while driving (fig.
9
, page 6).
If you have to use a roof vent instead of the air outlet vent:
➤
Cut out a section in the roof. Refer to the roof vent instruction manual for the
required dimensions. When doing so, observe the information, see chapter “Pre-
paring the installation” on page 17.
NOTE
At high ambient temperatures, the refrigerator can only provide its
maximum cooling capacity if the optimum ventilation has been
provided.