22
4.8
Gas installation
n
Observe the regulations stated in sec-
tion 4.1 .
n
This refrigerator is provided for installa-
tion within liquid gas equipment and
must be run exclusively on Universal gas
(no natural gas, town gas).
n
An AGA Approved LP Regulator must be
fitted to the gas supply. The pressure
regulator must concur with the opera-
ting pressure specified on the rating
plate of the appliance. The operating
pressure corresponds to the standad
pressure of the country of specification.
n
Only one connection pressure is permis-
sible for any one vehicle! A plate sho-
wing the permanent, clearly legible noti-
ce must be displayed in full view at the
point where the gas cylinder is installed.
n
The gas connection to the appliance
must be installed securely and free of
stress using pipe connectors and must
be securely connected to the vehicle .
n
The gas connection to the appliance is
1/8"BSP Female (s. figure 44).
n
The refrigerator must be equipped with a
shut-off valve allowing to cut the supply
line. Such a shut-off device must be rea-
dily accessible to the user.
* Specialised personnel are accredited experts who are
able, by virtue of their training and knowledge, to vouch
for the correct installation and implementation of the lea-
kage test.
The gas connection shall be carried out
by specialised personnel* only.
WARNING!
Fig. 44
CAUTION!
20 Nm
max
10 Nm
max
Testing point
Connection to gas supply
Gas burner
2
1
3
1
2
3
Gas connection
Gas pressure
Refer to data label.
Installation
Before Leaving
- Check all connections for
gas leaks with soap and water.
DO NOT
use
an unshielded flame for detecting leaks. Ignite
the burner to ensure correct operation of gas
valve, burner and ignition. When satisfied with
the appliance, please instruct the user on the
correct method of operation. In case the
appliance fails to operate correctly after all
checks have been carried out, refer to the aut-
horised service provider in your area.
i