14
Troubleshooting
Maintenance
EN 1949 stipulates that the appliance´s gas equipment and its associated fume
system must be inspected after installation and a certificate issued.
Afterwards a qualified technician must inspect according to EN 1949 every two
years and a certificate issued. It is the users responsibility to arrange for
inspections after purchase.
It is recommended that the gas burner be inspected and cleaned at
least once a year.
5.13
Failure 1: The refrigerator does not work in gas operation mode.
Possible cause
Action you can take
a.) Gas bottle empty?
b.) Is the supply cut-out device open?.
a.) Change gas bottle.
b.) Open the cut-out device.
Before calling the authorised Service department, please check whether:
1. The instructions in the section "Using the refrigerator" have been followed.
2. The refrigerator is not tilted excessiveley.
3. It is possible to operate the refrigerator with an available power source.
Failure 2: The refrigerator does not work on 12V.
Possible cause
Action you can take
a.) On-board fuse defective.
a.) Fit new fuse.
Failure 3: The refrigerator does not cool sufficiently.
Possible cause
Action you can take
a) Inadequate ventilation to the unit.
b) The thermostat setting is too low.
c) There is too much ice on the condenser.
d) Too much warm food put inside.
a) Check that the ventilation grilles are not
covered.
Check whether the refrigerator was instal-
led properly (Installation Guide).
b) Turn the thermostat to a higher setting.
c) Check that the refrigerator door seals
when shut.
d) Let food cool down first.
5.14
Summary of Contents for RM6275L
Page 17: ...17 Declaration of conformity 5 19 ...
Page 27: ...27 Wiring diagram 6 9 3 ...