12. Putting into operation
Technical data:
12.1. Connecting to electrical mains
The appliance may only be operated from
nominal voltage mains as shown on the data
plate. The appliance mains plug may be connected to
a mains socket earthed in accordance with regulations.
Any electrical work required to install this appliance
should be carried out by a qualified electrician or
competent person.
The manufacturer declines any liability should
these safety measures not be observed.
Electrical Requirements
Before switching on, make sure the electricity supply
voltage is the same as that indicated on the appliance
rating plate.
Only for UK:
The appliance is supplied with a 3 Amp plug fitted. In
the event of having to change the fuse in the plug
supplied, a 3 Amp ASTA approved (BS 1362) fuse
must be used. Should the plug need to be replaced
for any reason, the wires in the mains lead are
coloured in accordance with the following code:
(Details of the model, product- and serial-number
are to be found on the data label in the top left of
the inside compartment.)
In the event of a fault developing, contact your
nearest Service Centre-see local telephone
directory.
www.dometic.com
9
Model
RH 423LDA
RH 439LD
RH 449LD
Type
MB20-60
MB20-60
MB20-60
Gross volume
24 litres
28 litres
35 litres
Mains operation
220 - 240V (AC
220 - 240V (AC)
220 - 240V (AC)
Input
65W
65W
65W
Energy consumption
0,700 kWh/24h
0.650 kWh/24h
0.700 kWh/24h
Climate class
N
N
N
Refrigerant
159g H2O+86g NH3 147g H2O+98g NH3 147g H2O+98g NH3
GB
11. Customer service
Before you call a service engineer, carry out the
following simple tests:
If after checking all the above points, the refrigerator is
still not working satisfactorily, contact your nearest
service engineer. State the problem, model, product-
and serial-number.
Problem
The appliance does not cool sufficiently
The appliance does not cool at all.
Possible cause
Too much food to be cooled was put in.
Door is not shut properly.
Internal air circulation is restricted.
CUC system stopped the operation.
Plug is not connected to the mains socket properly
There is no voltage in the mains socket.
Solution
Put in less food to be be cooled.
Check if the door is shut.
Provide inside cool air circulation.
See operating instruction 5.3.
Check if the connection is proper.
Check if there is voltage.
Green and Yellow: Earth
Blue:
Neutral
Brown:
Live
The wire coloured green and yellow must be
connected to the terminal marked with the letter "E"
or by the earth symbol
or coloured green and
yellow.
The wire coloured blue must be connected to the
terminal "N" or coloured black.
The wire coloured brown must be connected to the
terminal marked "L" or coloured red.
* The energy consumption is measured at 12°C at 25°C environment
temperature (cellar).