background image

6

Figure 3.

Figure 4.

Figure 5.

5. Using the appliance

The cable for mains connection, the 12V connecting

cable  and  the  connector  for  the  gas  hook-up  are

located on the right-hand side of the rear cover of the

cooling box, behind the door (Figure 2).

5.1. Operating from electrical mains

Warning: Electrical grounding instructions:

This  appliance  is  equipped  with  a  three-prong

(grounding)  plug  for  your  protection  against  shock

hazards and should be plugged directly into a properly

grounded  three-prong  receptable.  Do  not  cut  or

remove the grounding prong from this plug.
The cord is approximately 5 feet long and a grounded

three-prong  receptable  should  be  installed  in  an

accessible  position  within  reach  of  the  plug.  Do  not

use any extension cords!
When connecting the appliance for the first time, set

the  thermostat  to  maximum;  then,  after  about  five

hours,  set  it  back  to  a  medium  position.  This  is

suitable for general refrigeration requirements.

NB:  Plug  is  provided  according  to  specific

regulations in each country and may be different to

that shown.

5.2. Operating from vehicle battery

Make sure the voltage shown on the data plate of the

appliance matches the voltage of the vehicle battery

(12V).
12V  DC  voltage  appliances  are  equipped  with

connectors that can be plugged into cigarette lighters

(Figure 3.). For some types of vehicle, you may need

to remove the red plastic ring located on the end of

the connector. To do so, turn the plastic ring in an anti-

clockwise direction and pull it off. The appliance can

then  be  connected  to  the  cigarette  lighter.  In  12V

operation,  the  appliance  runs  uninterrupted  without

temperature control.
For  12V  operation,  make  sure,  if  the  engine  is  not

running, that the appliance connector is removed from

the  cigarette  lighter.  Otherwise,  the  appliance  will

discharge the vehicle battery when in operation.

5.3. Liquid gas operation

Connection  to  the  gas  cylinder  is  described  in

sections 11.3. and 11.4. 
After opening the gas cylinder valve, push the safety gas

valve  down  (Figure  4)  and  set  it  to  the  large  flame

symbol, holding it down for about 10 seconds. Keep the

button pressed down and press the piezo-igniting button

(marked with a star) several times one after the other. If

the flame does not ignite, repeat the process. (Air in the

appliance gas line prior to connection to the gas cylinder

must be evacuated. Only then can the gas be lit.) 
Ignition of the flame can be verified through the flame-

view opening (Figure 5). After you have got the flame

keep the safety gas valve down another 20 seconds.

Figure 2.

Summary of Contents for PowerFridge RC3000

Page 1: ...207 5141 02 PowerFridge RC3000 Operating Instructions R USA CAN...

Page 2: ...trical operation the appliance can be used in an enclosed area However the appliance must still be protected from moisture For your safety If you smell gas 1 Evacuated enclosure 2 Call for professiona...

Page 3: ...e battery 5 3 Liquid gas operation 6 Mounting the wheels 7 Useful suggestions 8 Defrosting cleaning and maintenance 9 Customer service 10 Putting into operation technical data 10 1 Connecting to elect...

Page 4: ...is not damaged If you find damage to the appliance resulting from transport report it immediately to the transportation firm 2 View of the appliance 1 insulated casing 2 insulated lid 3 handle 4 cont...

Page 5: ...ances must be observed clearance from rear edge to outer casing of refrigerator 4 inches clearance above top of refrigerator lid 6 or 13 inches clearance at sides of refrigerator casing 0 inches Fig 2...

Page 6: ...of the vehicle battery 12V 12V DC voltage appliances are equipped with connectors that can be plugged into cigarette lighters Figure 3 For some types of vehicle you may need to remove the red plastic...

Page 7: ...folding it down beside the chassis In this position it acts as a leg when the appliance is in operation If you wish to pull the appliance on wheels make sure no power source is connected Then straigh...

Page 8: ...may cause these items to break On descent make sure the refrigeration unit does not roll onto your legs On steep descents proceed behind the unit with the wheels in front Once the refrigeration unit...

Page 9: ...nergy source is connected gas 120V 12V appliances must be connected to a vehicle cigarette lighter which is protected with a 16A fuse 10 3 Connecting to gas cylinder Make sure no other energy source i...

Page 10: ...frigeration unit The ozone friendly cyclopentane is activated as a motive agent for the PU foam insulation Sodium chromate is used for corrosion protection less than 2 weight of the coolant 13 Recycli...

Page 11: ...c Distribution Inc The Dometic Corporation 866 Langs Drive 509 South Poplar Street Cambridge Ontario LaGrange IN 46761 N3H 2N7 Canada Phone 219 463 4858 Phone 519 653 4390 For Service Center Assistanc...

Page 12: ...Printed by Xerox Hungary Ltd Rev 2003 09 03...

Reviews: