![Dometic PI8002 Installation, User And Service Manual Download Page 17](http://html1.mh-extra.com/html/dometic/pi8002/pi8002_installation-user-and-service-manual_2518555017.webp)
5. SERVICING
EN
17
5 SERVICING
WARNING
WARNING
The servicing shall be carried out only by authorized personnel.
WARNING
WARNING
Do not modify this appliance.
WARNING
WARNING
Before any servicing intervention shut off gas supply, disconnect all the electrical
power supplies and remove the appliance.
Hotplate: burners, injectors, thermocouples and ceramic igniters
1. Remove trivet (pan support) by pulling up from hotplate.
2. Remove screws from appropriate burner head disk. Remove head disk.
3. Remove burner by lifting straight up, taking care not to damage the thermocouple and ceramic igniter.
4. Using a 7mm spanner, unscrew the injector. When removing and fitting the injector, the injector holder
must be held in place with the aid of a tool (FIG. 9 - PG. 32)
5. Remove retaining washer from thermocouple head.
6. Disconnect appropriate thermocouple lead from gas cock.
7. Remove the thermocouple.
8. Remove retaining spring from ceramic igniter head.
9. Disconnect appropriate ceramic igniter lead from electronic igniter unit.
10. Remove the ceramic igniter.
11. Replace/ refit in reverse procedure.
Oven: injector, burner, thermocouple and ceramic igniter
1. From right hand side of appliance, remove spring from the oven burner inlet.
2. Using a 7mm spanner, unscrew the injector. When removing and fitting the injector, the injector holder
must be held in place with the aid of tool (FIG. 9 - PG. 32).
3. Remove lower heat shield at rear and tilt appliance forward.
4. Unscrew the oven burner mounts and lower burner.
5. Remove retaining nut from thermocouple head.
6. Disconnect the oven thermocouple lead from the gas cock.
7. Remove the thermocouple.
8. Remove retaining screw from ceramic igniter support.
9. Disconnect ceramic igniter lead from appropriate electronic igniter unit.
10. Remove the ceramic igniter.
11. Replace/ refit in reverse procedure.
Grill: injector, thermocouple, ceramic igniter and burner
1. From right hand side of appliance, remove spring from the grill burner inlet.
2. Using a 7mm spanner, unscrew the injector. When removing and fitting the injector, the injector holder
must be held in place with the aid of tool (FIG. 9 - PG. 32)
3. Remove the protection disk (not present in the CU4... models)
4. Remove retaining nut from thermocouple head.
5. Disconnect the grill thermocouple lead from the gas cock
6. Remove the thermocouple.
7. Remove retaining screw from ceramic igniter support.
8. Disconnect ceramic igniter lead from appropriate electronic igniter unit.
Summary of Contents for PI8002
Page 19: ...FIGURES AND TECHNICAL DRAWINGS EN 19 Figure 1 Figure 2 Figure 3 FIGURES ANDTECHNICAL DRAWINGS...
Page 27: ...FIGURES AND TECHNICAL DRAWINGS EN 27 CU403 CU403PE CU401 CU401PE CU402 CU402PE...
Page 28: ...FIGURES AND TECHNICAL DRAWINGS 28 IT EN FO311 PI0913 PI0913A PI8621A PI8621R PI8621S...
Page 30: ...FIGURES AND TECHNICAL DRAWINGS 30 IT EN VN555 MO8103 MO8123 Y X X 21 mm 25 mm 16 mm 21 mm...
Page 31: ...FIGURES AND TECHNICAL DRAWINGS EN 31 Figure 7 Figure 8...
Page 32: ...FIGURES AND TECHNICAL DRAWINGS 32 IT EN Figure 9...
Page 33: ...Notes...
Page 34: ......
Page 35: ......