![Dometic Oasis Elite Service Manual Download Page 4](http://html1.mh-extra.com/html/dometic/oasis-elite/oasis-elite_service-manual_2518010004.webp)
4
SECTION 1 WIRING
1.1
12VDC Supply Wire
1.1.1 The 12VDC supply wire must be run from
the 12VDC supply source to the Control
Box. It is recommended that these wires
be RED+ and Black– 12 gauge wires. This
needs to be on a separate 15 amp circuit.
See FIG. 1.1A & 1.1B.
1.1.2 To ensure proper operation, the control
box must have a minimum of 12.5 VDC at
the control box during operation. Check
voltage output on the Red and Black wire
at the control box. If voltage is below 12.5,
check voltage at supply, If OK it may be
necessary to increase the wire size going
to the control box. See FIG. 1.1A.
+12.5
VDC
12VDC
Power Supply
15 AMP
Breaker
Red +
Black-
*FUSE LOCATED INSIDE
Close
Open
FIG. 1.1A
1.1.3 If the control is the part number 3307930
& 3309114 the voltage can be checked
on the pins (1) and (2) of the 15 pin MATE-
N-LOK
®
plug. Pin (1) is DC+ and pin (2) is
DC-. See FIG. 1.1B
1.2 Wire From Control Box to Awning. Arm As-
sembly (WeatherPro) and Awning Motor (Oa-
sis Elite)
A Red and Black Wire (WeatherPro) Red/White
and Blue or Black/White wire (Oasis Elite) of
adequate size must be run between the control
box and the awning. To avoid voltage drop fol-
low the chart below to determining the proper
size wire to be used.
Wire Length
Wire Size
10' & Under
14 Gauge
11' to 30'
12 Gauge
Over 30'
10 Gauge
AMP UNIVERSAL MATE-N-LOK
Soft Shell Connector
R
13
10
7
4
1
14
8
5
2
15
12
3
11
9
6
Oasis
Elite
FRTA
Red/White (12)
Blue or BlK/Wh (7)
Red
12VDC
+
(1)
Black
12VDC
-
(2)
WeatherPro
Awning
Main Arm
Right Side
Red (13)
Black (8)
AMP 2-Pin
Connector
1
2
Green/White (4)
Brown/White (14)
Yellow/White (9)
Oasis
Elite
Remote
Switch
Green (5)
Brown (15)
Yellow (10)
WeatherPro
Remote Switch
Pink (3)
Ignition
Isolator
13
10
7
4
1
14
8
5
2
15
12
3
11
9
6
1
2
Black 1
Red 2
Green 3
Yellow 4
Wind Sensor Switch
ENABLE (ON)
DISABLE (OFF)
Cable to Wind Sensor
18-20 Gauge
(18 Foot Maximum)
Cable to Wind Sensor
18-20 Gauge
(18 Foot Maximum)
Cable Between MATE-N-LOK
4 Pin Connectors
Customer Supplied
18-20 Gauge
(18 Foot Maximum)
*FUSE LOCATED INSIDE
Close
Open
Auto Resettable Fuse
Used On Some Models
3307930 & 3309114 Control Box Kit Using
Universal MATE-N-LOK
R
Soft Shell Connector
FIG. 1.1B
1.3 Wire Inside Hardware Channel (WeatherPro Only)
To make the connection between the wire run in
1.2 and the awning motor there is a cable run in
the hardware from the bottom to the top. Check
this wire for pinches or breaks. If wire is defec-
tive replace with new harness. See FIG. 1.3.
FIG. 1.3
Cable
Cable
WeatherPro
Main Arm
Right Side
Pig Tail to
Control Box
End
Pig Tail
for Motor
Oasis Elite
Motor
Black
Red
Red
Black
Red/White
Black or Blue
Black
Red
Blue or Blk/Wh
Red
*FUSE LOCATED INSIDE
Close
Open
FIG. 1.2
Pin 1
12+VDC
Red
12 Gauge
Pin 2
12- VDC
Black
12 Gauge
Pin 3
Ignition Isolator
Pink
16 Gauge
Pin 4
Oasis Elite Remote Switch
Green/White
16 Gauge
Pin 5
WeatherPro Remote Switch
Green
16 Gauge
Pin 6
Blank
Pin 7
Oasis Elite Motor (-12VDC)
Blue or Blk/Wh See chart in 1.2
Pin 8
WeatherPro Motor (-12VDC)
Black
See chart in 1.2
Pin 9
Oasis Elite Remote Switch
Yellow/White
16 Gauge
Pin 10
WeatherPro Remote Switch
Yellow
16 Gauge
Pin 11
Blank
Pin 12
Oasis Elite Motor (+12VDC)
Red/White
See chart in 1.2
Pin 13
WeatherPro Motor (+12VDC)
Red
See chart in 1.2
Pin 14
Oasis Elite Remote Switch
Brown/White
16 Gauge
Pin 15
WeatherPro Remote Switch
Brown
16 Gauge
Location
Pin Functions
Wire Color
Wire Size
Right Arm
Assembly