EN
MSI
Technical data
29
15
Technical data
I
NOTE
In the event of thermal overloading, the inverter reacts by reducing the
power for temperatures of 40 °C and above.
If the temperature exceeds 60 °C, the inverter switches off.
MSI912
MSI1812T
Rated input voltage:
12 V
g
Output power
at 25 °C for 10 min:
900 W
1800 W
Continuous output power
at 25 C:
800 W
1600 W
Peak output power:
1600 W
3200 W
Output voltage:
200 – 240 V
w
pure sine wave (THD < 3 %)
Output frequency:
50 or 60 Hz
Idle current consumption:
1.8 A
2.1 A
Standby current
consumption:
0.5 A
Input voltage range:
10.5 V – 16 V
Efficiency up to:
89 %
90 %
Bypass relay:
–
25 A/277 V
w
Ambient temperature for
operation:
–20 °C to 40 °C
40 °C to 60 °C (reduced power)
Ambient temperature for
storage:
–30 °C to +70 °C
Priority circuit:
–
230 V input protection: 10 A
Switchover time of bypass
relay:
< 30 m sec
Dimensions W x D x H:
197.5 x 94.3 x 291 mm, see
fig.
d
, page 30
197.5 x 94.3 x 406 mm
see fig.
d
, page 30
Weight:
4 kg
6 kg
MSI912-1812T-IO-AU.book Seite 29 Freitag, 23. Dezember 2016 3:11 15