background image

7

Pull the door together with the hinge away from the housing and up off

the lower hinge bolt (2-3).
Remove screws (4) and pull off the frame edge (5).
Slide the decorative panel (6) out of the door frame and insert the new

panel (7), so that the upper edge of the panel runs exactly parallel to

the upper edge of the frame. A new panel can be inserted more easily

into the upper edge of the frame when the two corners are cut off by

approx. 5 x 5mm (8). Put the frame edge (5) back in place and secure

with screws.
Place the door on the lower hinge (9), slot the upper hinge into the

opening, press together with the door against the housing and secure

with the two screws (11).

12. Changing the feet 

(Fig. 10)

Should you wish to install your miniCool, you will not need the 40-mm

feet. After having removed the 40-mm feet, you can then re-attach the

12-mm feet, located inside the 40-mm feet, to the front and rear fixing

points.  The  40-mm  feet  and  the  4  remaining  screws  should  be

retained for future use.

13. Assembly of door handle 

(Fig. 11)

14. Customer service

Before  you  call  a  service  engineer,  carry  out  the  following  simple

tests:

Is there a power failure? Check the fuses.
Is  the  plug  firmly  connected  to  the  socket  and  is  the  socket

switched on? Check the socket by plugging in another appliance,

e.g. a table lamp.
Is the thermostat at the correct setting? (normally 3 or 4).
Has  the  door  not  been  closed  properly  causing  the  inside

temperature to rise too quickly?
Is the refrigerator level?
Has the ventilation become obstructed?

If after checking all the above points, the refrigerator is still not working

satisfactorily,  contact  your  nearest  service  engineer.  State  the

problem, model, product- and serial-number.
(Details of the model, product- and serialnumber are to be found on

the data label in the top left of the inside compartment.)

This  refrigerator  is  equipped  with  overheating  protection.  An

authorised service technician can check whether this has been

triggered or not.

In  the  event  of  a  fault    developing,  contact  your  nearest    Service

Centre-see local telephone directory. 

Figure 9.

Figure 10.

Figure 11.

GB

Figure 8.

All manuals and user guides at all-guides.com

Summary of Contents for miniCool EA 0600

Page 1: ...l IT FR DE NL ES PT GB Operating Instructions Bedienungsanleitung Mode d emploi Istruzioni per l uso Handleiding Manual de Instrucciones Instru es de Utiliza o Bruksanvisning Bruksanvisning Betjenings...

Page 2: ...ossible content loss See installation instructions Parts which heat up should not be exposed Wherever possible the back of the product should be close to a wall but leaving the required distance for v...

Page 3: ...ful suggestions 8 Defrosting cleaning and maintenance 9 Changing the lightbulb 10 Reversing the door hang 11 Replacing the decorative door panel 12 Changing the feet 13 Assembly of door handle 14 Cust...

Page 4: ...the transportation firm 2 View of the appliance EA 3210 EA 3200 IN CASE IF YOUR REFRIGERATOR IS EQUIPPED WITH LOCK DOMETIC RT DO NOT ACCEPT LIABILITY FOR LOSS OR DAMAGE OF KEYS HOWEVER WE WOULD BE HA...

Page 5: ...gned for free standing installation but can be built in if the following conditions are complied with to ensure satisfactory operation and maximum cooling efficiency IMPORTANT Please follow the instal...

Page 6: ...y ice formation every 2 3 months This is carried out as follows Set the thermostat at 0 disconnect at the mains remove food and ice dish and leave the doors open Do not expose the refrigerator to exte...

Page 7: ...future use 13 Assembly of door handle Fig 11 14 Customer service Before you call a service engineer carry out the following simple tests Is there a power failure Check the fuses Is the plug firmly co...

Page 8: ...0 240V AC 220 240V AC Input 115W 115W Energy consumption 1 4 kWh 24h 1 4 kWh 24h Climate class N N Refrigerant 525g NH3 H2O 540g NH3 H2O 16 Environmental protection information The appliance does not...