EN
Troubleshooting
HiPro
28
No cooling, absorber
unit warm
Refrigerator is not level
Align refrigerator with
water level
Refrigerator was only switched on
recently
Check cooling again after
5 to 6 hours
Cooling unit is defective
Authorized service:
Replace refrigerator
No cooling, interior
light and door opening
monitor (optional) flash
continuously
Refrigerator is not level
Align refrigerator with
water level
Cooling unit blocked
Contact authorized cus-
tomer service
Cooling unit not water-tight
Heating element defective
Error during self-test
Poor cooling perfor-
mance
Cooling unit not sufficiently ventilated Bring about sufficient ven-
tilation (fig.
Refrigerator is exposed to direct sun-
light
Take refrigerator out of
direct sunlight
Door of refrigerator does not close
with a tight seal
Check distances (fig.
Authorized service:
Replace door seal
Refrigerator was recently filled
Check cooling again after
5 to 6 hours
Frost formation in the
refrigerator compart-
ment
Door of refrigerator does not close
with a tight seal
Check distances (fig.
Authorized service:
Replace door seal
Fault
Possible cause
Solution
DometicHiPro3000-4000-6000-Vision_IOM_4445102742_APAC(en)_202x-xx-xx.book Seite 28 Mittwoch, 17. März 2021 1:37 13