5.5   POWER OUTPUT

The Inverter will operate most AC loads within its power rating.  When determining whether 

a microwave oven can be operated by the Inverter, remember that the power commonly 

advertised for microwave ovens is the cooking power (the power delivered to the food), not the 

power actually consumed by the microwave oven.  The microwave oven will consume 40% to 

100% more than its advertised cooking power.  Check the rating sticker on the back of the oven 

to determine its actual power draw.
Some induction motors used in refrigerators, freezers, pumps, and other motor operated 

equipment require very high surge currents to start.  The Inverter may not be able to start some 

of these motors, even though their rated current draw is within the Inverter.
If the motor refuses to start, observe the battery voltage indicator while trying to start the motor.  

If the battery voltage indicator drops below 11V while the Inverter is attempting to start the 

motor, this may be why the motor will not start.  Make sure that the battery connections are 

good and that the battery is fully charged.  If the connections are good and battery is charged, 

but the voltage still drops below 11V, you may need to use a larger battery.
The following table shows the typical power consumption of common devices. Actual device 

wattage requirements will vary. Some devices listed may require a pure sine wave Inverter 

instead or proper operation.

Device

Wattage

Coffee Maker

850

Iron

1050

Mini Microwave

1200

Hair Dryer

1200

10” Saw

1350

DEVICE

WATTAGE

Laptop

50

Stereo

200

Mixer

200

Table Fan

200

Computer

250

Small Refrigerator

350

Jigsaw

350

DEVICE

WATTAGE

Belt Sander

350

3/8” Drill

350

Blender

350

Food Processor

400

Reciprocating 

Saw

600

Vacuum

750

Chest Freezer

800

OPERATION

Summary of Contents for Go Power! GP-1750HD

Page 1: ...nual GP 1750HD GP 3000HD GP 5000HD 2021 Go Power Worldwide Technical Support and Product Information gpelectric com Go Power Dometic 201 710 Redbrick Street Victoria BC V8T 5J3 Tel 1 866 247 6527 8069...

Page 2: ...17 4 6 BATTERY PRECAUTIONS 19 4 7 DC WIRING SIZING 20 4 8 DC GROUNDING 21 5 OPERATION 22 5 1 OPERATING PRECAUTIONS 22 5 2 CONNECTING AC LOADS 23 5 3 CONTROLS AND INDICATORS 23 5 4 OPTIONAL ON OFF REM...

Page 3: ...national electrical codes These instructions are for use by qualified personnel who meet all local and governmental code requirements for licensing and training for the installation of electrical powe...

Page 4: ...any way See the Warranty section for instructions on returning the equipment WARNING Hazard to Human Life This type of notation indicates that the hazard could be harmful to human life WARNING Shock H...

Page 5: ...omponents If the equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired People with pacemakers should consult their physician s before...

Page 6: ...NING Fire Hazard Do not keep combustible or flammable materials in the same room with the equipment Some products contain relays with moving parts and are not ignition protected Ensure AC DC and groun...

Page 7: ...smoke or allow a spark or flame near the batteries Always use insulated tools Avoid dropping tools onto batteries or other electrical parts Never charge a frozen battery Never use old or untested bat...

Page 8: ...s If battery acid contacts skin or clothing wash immediately with soap and water If acid enters the eye immediately flood it with running cold water for at least 20 minutes and get medical attention a...

Page 9: ...her representation warranty or guarantee that the information is accurate correct reliable or current The specifications in this manual are for reference purposes only and are subject to change withou...

Page 10: ...2 FEEL FREE TO MOVE RESIZE THIS TABLE MATERIAL FINISH FINISH SPEC COLOR A B C 6 7 8 ALL COMPONENTS AND PROCESSES TO BE ROHS COMPLIANT CERTIFICATE REQUIRED WITH INITIAL SHIP NOTES 1 TYPE YOUR NOTES IN...

Page 11: ...ED DATA COPYRIGHT 2012 BY Carmanah Technologies Corp Victoria BC Canada ALL RIGHTS RESERVED NO PART OF THIS DOCUMENT MAY BE REPRODUCED STORED IN A RETRIEVAL SYSTEM OR TRANSMITTED IN ANY FORM WITHOUT T...

Page 12: ...USB OUTPUT VOLTAGE 4 75 5 25 VDC 2 1 A OUTPUT WAVEFORM MODIFIED SINE WAVE AC OUTPUT CONNECTIONS 3 STANDARD NORTH AMERICAN OUTLETS USB CONNECTIONS 1 USB PORTS SIGNAL AND CONTROL REMOTE CONTROLLER PANE...

Page 13: ...USB OUTPUT VOLTAGE 4 75 5 25 VDC 2 1 A OUTPUT WAVEFORM MODIFIED SINE WAVE AC OUTPUT CONNECTIONS 4 STANDARD NORTH AMERICAN OUTLETS USB CONNECTIONS 1 USB PORTS SIGNAL AND CONTROL REMOTE CONTROLLER PANE...

Page 14: ...N USB OUTPUT VOLTAGE 4 75 5 25 VDC 2 1 A OUTPUT WAVEFORM MODIFIED SINE WAVE AC OUTPUT CONNECTIONS 4 STANDARD NORTH AMERICAN OUTLETS USB CONNECTIONS 1 USB PORTS SIGNAL AND CONTROL REMOTE CONTROLLER PAN...

Page 15: ...wer supply with lower voltage will not oper ate the Inverter correctly and higher voltage could damage the Inverter 5 Connect input polarity properly Incorrect connection will damage the Inverter and...

Page 16: ...internal temperature gets too high Note even though this Inverter has built in mechanisms to minimize damage these situations should be avoided because they can still damage the Inverter or battery 4...

Page 17: ...member the terminal is positive and the terminal is negative Place the lug connector between the washers and tighten the terminal screw or nut to clamp the wires securely Ensure connections are tight...

Page 18: ...of flammable fumes as explosion or fire may result 8 Set the power switch to the ON position Check the meters and indicators on the front panel of the Inverter The Function LEDs should be green showin...

Page 19: ...minals together to the other cable The following points must be observed for the DC Wiring The DC positive and negative cables connected to the Inverter from the battery bank should be linked together...

Page 20: ...o prevent frequent low input voltage warnings and shutdown Only use high quality copper wire The cables should be as short as possible and the overall length of both cables added together should be le...

Page 21: ...referred to as the Earth ground or another designated ground For example on an RV the metal frame of the RV is designated as the negative DC ground RV ground The DC ground wire connection on the Inver...

Page 22: ...ce becomes extremely hot turn the power remove the device and do not use with the Inverter 5 Check for breakage of parts and any other condition that may affect the Inverter s operation If damaged hav...

Page 23: ...ge the battery to the point that it will no longer start the engine If needed operate the engine pe riodically to maintain the batteries charge Do not operate a vehicle s engine in an enclosed space 5...

Page 24: ...r refuses to start observe the battery voltage indicator while trying to start the motor If the battery voltage indicator drops below 11V while the Inverter is attempting to start the motor this may b...

Page 25: ...arged but the voltage still drops below 11 volts you may need to use a larger battery 5 6 INPUT VOLTAGE The Inverter will operate from input voltage ranging 10 5 16V If the voltage drops below 10 5 V...

Page 26: ...replace battery 5 Clean and tighten connection 6 Remove charging source and make sure correct battery is being used and connected correctly OUTPUT VOLTAGE IS INCORRECT Input voltage is too high or to...

Page 27: ...erson using only identical replace ments This will ensure that the safety of the Inverter is maintained 4 Fuses must be replaced with fuses of the same type and rating only 7 2 MAINTENANCE Very little...

Page 28: ...leshoot the problem If trouble persists 1 Call your Go Power Technical Support team 1 866 247 6527 or 2 Return defective product to place of purchase Unless approved by Go Power Management all product...

Page 29: ...e Knowing for sure if your appliances are being recycled properly is tricky If you re in doubt just ask Recyclers that are certified should gladly show you their certification If the re cycler is cert...

Page 30: ...2021 Go Power Worldwide Technical Support and Product Information gpelectric com Go Power Dometic 201 710 Redbrick Street Victoria BC V8T 5J3 Tel 1 866 247 6527 80691_MANUAL_GP 1750 3000 5000 HD_RevC...

Reviews: