Dometic DuraSea Installation & Operation Manual Download Page 1

COPYRIGHT © 2011-2012 Dometic Group. All Rights Reserved.

No part of this publication may be reproduced, translated, stored in a retrieval system, or transmitted in any form or by any means 
electronic, mechanical, photocopying, recording or otherwise without prior written consent by Dometic Group. Every precaution has 
been taken in the preparation of this manual to ensure its accuracy. However, Dometic Group assumes no responsibility for errors and 
omission. Neither is any liability assumed for damages resulting from the use of this product and information contained herein.

DuraSea Rooftop Air Conditioner

120 VAC / 60 Hz Model

I

NSTALLATION

 & O

PERATIONS

 M

ANUAL

Use with Air Distribution Box (not included)

Control: Integral Mechanical

Dometic Marine
Rev. 20120412
L-3075 English

Summary of Contents for DuraSea

Page 1: ...Group Every precaution has been taken in the preparation of this manual to ensure its accuracy However Dometic Group assumes no responsibility for errors and omission Neither is any liability assumed...

Page 2: ...UNIT ON THE ROOF 6 INSTALLING THE UNIT 6 WIRING SYSTEM TO POWER SUPPLY CONNECTION 9 AIR DISTRIBUTION BOX INSTALLATION 10 Operating Instructions 11 CONTROLS 11 OFF Position 11 Cooling Operation 12 Heat...

Page 3: ...can support 130 pounds 59 kg of weight when the boat is in motion If applicable Roof construction with rafters joists on minimum of 16 inch 40 64 cm centers Minimum of 1 inch 2 54 cm and maximum of 4...

Page 4: ...faces Specifications Table 1 Product Specifications Model 115 VAC 60 Hz Nominal Capacity BTU hr Cooling 15 000 Electrical Rating 120 VAC 60 Hz 1 Phase Running Amps 15 3 Compressor Locked Rotor Amps 66...

Page 5: ...determining your cooling requirements the following should be considered Size of boat Window area increases heat gain Amount of insulation in walls and roof Geographical location where the boat will...

Page 6: ...requirement Check inside the boat s cabin for obstructions to the air distribution box i e space for doors to open room dividers curtains ceiling fixtures etc See Figure 2 Figure 2 Interior Dimension...

Page 7: ...359 mm it must be enlarged to 14 25 x 14 25 1 8 or 362 x 362 mm 3 mm NEW OPENING INSTALLATION OTHER THAN VENT OPENING 1 Mark a 14 25 x 14 25 1 8 or 362 x 362 mm 3 mm square on the roof and carefully...

Page 8: ...rdered separately inside the boat This box contains mounting hardware for the unit and will be used inside the boat 3 Place the unit on the roof 4 Lift and place the unit over the prepared opening usi...

Page 9: ...over blower discharge See Figure 6 Note Edges without flanges install toward REAR and SIDE of opening See Figure 6 Figure 6 Align Distribution Box s Upper Duct With Blower Discharge 5 Use two 2 10 x...

Page 10: ...mplate up to the 14 25 x 14 25 1 8 or 362 x 362 mm 3 mm opening Start each mounting bolt through the ceiling template and up into the base pan by hand See Figure 9 Tighten all 4 bolts until they touch...

Page 11: ...ground screw Tighten connector making sure not to damage wires 3 Connect white to white black to black using approved connectors Connect the bare copper wire to the ground screw located in the juncti...

Page 12: ...ole plug into place at rear of air distribution box See Figure 14 4 There are four optional mounting holes on the outer edge of the return air opening for which screws are not provided These are only...

Page 13: ...structions CONTROLS 1 The Selector Switch has 8 positions including OFF This controls fan speed heating mode optional and cooling modes See Figure 15 2 The Thermostat controls the temperature range at...

Page 14: ...e air in your boat without cooling or heating There are three positions HIGH FAN MED FAN or LOW FAN to select from depending upon personal choice Maintenance AIR FILTER Periodically a minimum of every...

Page 15: ...the manufacturer or its service agent or a similarly qualified person 4 When calling for service always give the following Unit type and serial number found on the identification label located on bas...

Page 16: ...Frost Formation On Cooling Coil DuraSea Rooftop Installation Operations Manual 14 L 3075 ENGLISH Wiring Diagrams Figure 16 Unit Wiring Diagram Figure 17 Air Distribution Box Wiring Diagram...

Page 17: ...liability or expense except as is specifically authorized and provided in this section Dometic reserves the right to improve its products through changes in design or material without being obligated...

Page 18: ...and the date it is put in service In such instances the date of manufacture could indicate that the item is out of warranty However based on the date the equipment is first put in service the item ma...

Page 19: ...ginal owner s warranty based on the original date of purchase or date of installation 2 Proof of purchase or installation may be required to verify warranty coverage 3 Any unit or replacement part ins...

Page 20: ......