![Dometic Duo-Therm 3308417.009 Installation Instructions Manual Download Page 7](http://html1.mh-extra.com/html/dometic/duo-therm-3308417-009/duo-therm-3308417-009_installation-instructions-manual_2518229007.webp)
7
579 & 595 Installation Instructions
These items must be determined in conjunction with the Air
Distribution System and Sizing and Design Require-
ments listed in the chart on page 6. Terminate the start
of the duct at the back edge of the 14-1/4" x 14-1/4" (±1/
8" opening)
Important:
Alternate configurations and methods
may be used which still allow the air conditioner to
operate properly; however, these alternate configura-
tions and methods must be approved by the Dometic
Corporation in writing. The following instructions are
based upon the use of Dometic Return Air Kits 3105007
Return Air Cover, 3105935 Quick Cool Return Air Cover
or 3308120 Genesis Air Filtration System. The
3107180.006 Bolt/Cover Kit has the mounting bolts and
cover for the AC junction box for use with these kits.
FRAME
14-1/4" (±1/8”)
OPENING
AC POWER
SUPPLY WIRE
DUCT
FRAME
DUCT
ROOF
INSULATION
DUCT
CEILING
DUCT
14-1/4" (±1/8”)
OPENING
INSULATION
SIDE VIEW
(TOWARD BACK OF RV)
TOP VIEW
(BACK OF RV)
LOW VOLTAGE WIRES:
12VDC
Furnace
Load Shed
Sensors
FRAME
CCC, CONTROL CABLE(S)
or 7-Wire Analog Cable
FIG. 7A
Register Required
FIG. 7B
FIG. 7C
Duct Size And Requirements For 3105007 And 3105935 Return Air Cover
Duct Size And Requirements For 3308120 Genesis Air Filtration System Kit
Total Outlet Air Area
Minimum 21.0 Sq. In.
Total Outlet Air Area
Minimum 32.0 Sq. In.
Register Required
Register Required
Register Required
Register Required
Register Required
Register Required
Register Required
Roof
Rafters
Roof
Rafters
Note: Duct Size is Inside Dimensions
Note: Duct Size Is Inside Dimensions
Short Duct Run Minimum
1/3 Total Duct Length
Short Duct Run Minimum
1/3 Total Duct Length
Ducts
Min.
Max.
Depth
1-1/2”
2-1/2”
Width
7.0”
10.0”
Total Length
15.0’
40.0’
Ducts
Min.
Max.
Depth
2.0”
2-1/2”
Width
8.0”
10.0”
Total Length
15.0’
40.0’
14-1/4"x14-1/4" (±1/8")
Roof Opening
14-1/4"x14-1/4" (±1/8")
Roof Opening
Registers
4 Min.-- 8 Max.
(Per Unit)
14 Sq. In Free Area
Per Register
Registers
4 Min.-- 8 Max.
(Per Unit)
14 Sq. In Free Area
Per Register
RECEIVER
CABLE
Summary of Contents for Duo-Therm 3308417.009
Page 18: ......