7-17
Normal:
Approximately
25 to 45 ohm
Normal:Approximately
Abnormal:
Infinite or several.
Normal:
Approximately 250 to 350
Kohm at 68 ± 35°F
Abnormal:
Infinite or several.
Normal: Approximately
Abnormal:
Infinite or several.
Normal: Approximately
at 68 ± 35°F
Abnormal:
Infinite or several.
COMPONENTS
TEST RESULTS
VENTILATION MOTOR
1
2
3
DAMPER MOTOR (D.M)
TURNTABLE MOTOR (T.M)
STIRRER MOTOR (S.M)
THERMISTOR
HEATER ELEMENT
SENSOR
1. Remove wire leads.
2. Measure resistance.
(ohm meter scale: Rx1)
1. Remove wire leads.
2. Measure resistance.
(ohm meter scale: Rx1000)
1. Remove the connector from PCB
2. Measure resistance across pins 1 & 3.
(ohm meter scale: Rx1)
1. Remove wire leads.
2. Measure resistance.
(ohm meter scale:Rx1)
1. Remove the 3 pin connector from PCB.
2. Measure resistance across pins 1 & 2.
3. Across pins 2 & 3.
(ohm meter scale:Rx1)
D.M
T.M
S.M
2.3-3.5
2.6-3.5 100-170
Kohm
Kohm
ohm
Conv. HTR
15-25
1 & 2
2 & 3
3.1 Kohm
∞