The minibar is set by default to a cooling temperature of 7 °C (47 °F) at an ambient
temperature of 25 °C (77 °F).
You can use the setting button (fig.
4
page 4) to set the cooling temperature to
one of three values: 5 °C, 12 °C and 7 °C (41 °F, 54 °F and 45 °F).
Thereby the temperature will be changed in the order 5 °C … 12 °C … 7 °C … 5 °C
(41 °F … 54 °F … 45 °F … 41 °F) etc.
➤
Press the setting button (fig.
,
page 4) and keep it pressed for 5 s, until the
lamp (fig.
1
page 4) starts to blink.
➤
Press immediately the setting button (fig.
4
page 4) again.
✓
The lamp (fig.
,
page 4) indicates the setting temperature:
–
5 °C (41 °F): the lamp flashes five times in three intervals
–
12 °C (54 °F): the lamp flashes once in three intervals
–
7 °C ( 45 °F): the lamp flashes three times in three intervals
I
8
Troubleshooting
NOTE
The minibar sets the cooling temperature automatically to 7 °C (47 °F),
when it is connected to a power source.
Fault
Possible cause
Suggested remedy
Device does not
function, Status LED
does not glow.
No voltage present in
the AC voltage socket.
Try using another plug socket.
The mains adapter is
defective.
Contact service agent.
The device does not
cool (plug is inserted,
Status LED glows).
The cooling element is
defective.
Contact service agent.
The Error LED flashes
once per second.
Temperature sensor is
defective.
Contact service agent.
The Error LED flashes
twice per second.
The fan is defective.
Contact service agent.
Device does not cool
sufficiently, Status LED
glows, Error LED does
not glow.
The cooling element is
defective.
Contact service agent.
Poor ventilation
Check the ventilation.
Clean the filter underneath the device.
DometicDM20D-DM20F_IOM_4445101915_AMER(en-fr-es)_20x-xx-xx.book Seite 20 Dienstag, 22. Dezember 2020 5:06 17